9.9  APPENDIX I:  Mounting Configurations 
External 
Chamber 
MINIMUM  
DIELECTRIC 
CONSTANT 
MAXIMUM  
PROBE 
LENGTH 
1.7 
20 ft./6.1 m 
30 ft./9.1 m 
10 
50 ft./15.2 m 
35 
50 ft./15.2 m 
Coaxial 
Probe 
MINIMUM  
DIELECTRIC 
CONSTANT 
MAXIMUM  
PROBE 
LENGTH 
1.4 
20 ft./6.1 m 
20 ft./6.1 m 
10 
100 ft./30.5 m 
Dual Rod 
Flat Plate Or 
 Coupling 
MINIMUM  
DIELECTRIC 
CONSTANT 
MAXIMUM  
PROBE 
LENGTH 
20 ft./6.1 m 
20 ft./6.1 m 
10 
100 ft./30.5 m 
Dual Rod 
Nozzle & 
Flange 
MINIMUM  
DIELECTRIC 
CONSTANT 
MAXIMUM  
PROBE 
LENGTH 
2.5 
20 ft./6.1 m 
20 ft./6.1 m 
10 
100 ft./30.5 m 
Flat Plate  
Or 
 Coupling 
Nozzle  
&  
Flange 
Permanent 
Stilling Well 
MINIMUM  
DIELECTRIC 
CONSTANT 
MAXIMUM  
PROBE 
LENGTH 
20 ft./6.1 m 
10 
40 ft./12.2 m 
35 
100 ft./30.5 m 
1.3
100 ft./30.5 m 
MINIMUM  
DIELECTRIC 
CONSTANT 
MAXIMUM  
PROBE 
LENGTH
 
20 ft./6.1 m 
10 
40 ft./12.2 m 
35 
100 ft./30.5 m 
1.3
1
 
100 ft./30.5 m 
MINIMUM  
DIELECTRIC 
CONSTANT 
MAXIMUM  
PROBE 
LENGTH 
1.7 
20 ft./6.1 m 
30 ft./9.1 m 
10 
50 ft./15.2 m 
35 
50 ft/15.2 m 
MINIMUM  
DIELECTRIC 
CONSTANT 
MAXIMUM  
PROBE 
LENGTH 
1.7 
20 ft./6.1 m 
30 ft./9.1 m 
10 
50 ft./15.2 m 
35 
50 ft/15.2 m 
Removable 
Stilling Well 
1. 
Accuracy subject to changes in dielectric constant.  Ultra-Low Dielectric (ULD) measurement method supports dielectric 
constants from 1.3 to a maximum of 2.0.  
 
 
 
 
 
 
 
 
1, 2 
3a, 3b 
9, 10a, 
10b 
Figure 9.4