916
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
B Instruction Execution Time
B-5 Execution Time of Pulse Generation Instruction P in Each Applied Instruction
Appendix B-5 Execution Time of Pulse Generation Instruction P in Each Applied
Instruction
• FX
3U
/FX
3UC
PLCs
• FX
3G
PLCs (Standard mode)
Applied instruction
Execution time
Remarks
MOV instruction (FNC 12)
Execution time at rising edge of input: Execution time in ON status
1.22
µs in MOVP instruction
Non-execution time: Execution time in OFF status
Other applied instructions
Execution time at rising edge of input: Execution time in ON status + 0.45
µs
Non-execution time: Execution time in OFF status + 0.45
µs
Non-execution time: Execution time in OFF status + 0.45
µs
Applied instruction
Execution time
Remarks
MOV instruction (FNC 12)
Execution time at rising edge of input: Execution time in ON status = 4.98
µs
Non-execution time: Execution time in OFF status = 0.8
µs
BCD instruction (FNC 18)
Execution time at rising edge of input: Execution time in ON status = 5.03
µs
Non-execution time: Execution time in OFF status = 0.75
µs
BIN instruction (FNC 19)
Execution time at rising edge of input: Execution time in ON status = 5.03
µs
Non-execution time: Execution time in OFF status = 0.75
µs
ADD instruction (FNC 20)
Execution time at rising edge of input: Execution time in ON status = 6.37
µs
Non-execution time: Execution time in OFF status = 0.75
µs
SUB instruction (FNC 21)
Execution time at rising edge of input: Execution time in ON status = 6.47
µs
Non-execution time: Execution time in OFF status = 0.75
µs
MUL instruction (FNC 22)
Execution time at rising edge of input: Execution time in ON status = 7.07
µs
Non-execution time: Execution time in OFF status = 0.75
µs
DIV instruction (FNC 23)
Execution time at rising edge of input: Execution time in ON status = 7.03
µs
Non-execution time: Execution time in OFF status = 0.75
µs
INC instruction (FNC 24)
Execution time at rising edge of input: Execution time in ON status = 3.48
µs
Non-execution time: Execution time in OFF status = 0.75
µs
DEC instruction (FNC 25)
Execution time at rising edge of input: Execution time in ON status = 3.48
µs
Non-execution time: Execution time in OFF status = 0.75
µs
WAND instruction (FNC 26)
Execution time at rising edge of input: Execution time in ON status = 6.42
µs
Non-execution time: Execution time in OFF status = 0.75
µs
WOR instruction (FNC 27)
Execution time at rising edge of input: Execution time in ON status = 6.42
µs
Non-execution time: Execution time in OFF status = 0.75
µs
WXOR instruction (FNC 28)
Execution time at rising edge of input: Execution time in ON status = 6.42
µs
Non-execution time: Execution time in OFF status = 0.75
µs
Other applied instructions
Execution time at rising edge of input: Execution time in ON status + 0.45
µs
Non-execution time: Execution time in OFF status + 0.45
µs