CONTROL CABLE SIGNALS
2001 NEW
■ Terminal information
Consider the following points when using a non-Icom
transceiver.
Start voltage [STAR]
When a start voltage (less than 1 V) is received, the
AT-141 begins automatic tuning.
Key voltage [KEY]
During automatic tuning, the AT-141 grounds the key
voltage line, and the HF transceiver reduces output
power.
8
6
4
2
0
Time
Key 
voltage 
[V]
Grounded
Approx. 7.5 V
During automatic tuning
8
6
4
2
0
Time
More than 
350 msec.*
Approx. 7.5 V
Less than 1 V to 
start tuning
Start 
voltage 
[V]
*For tuner through operation; Less than 250 msec. 
[KEY]
[STAR]
[13.6]
[ANTC]
Terminal
Description
[KEY]
Key voltage. Grounded during tuning. 
Max. current drain 100 mA.
[13.6]
13.6 V DC + input terminal. 
Max. current drain 2 A
[STAR]
Receives start voltage. 
Max. current drain 1 mA
[ANTC]
Antenna current detector output.
AT-141_0.qxd  05.12.1 11:06  Page 6