Листовка для Aero Mist 60100K

Скачать
Страница из 2
Regulator
(Normal operating pressure 800-1000 PSI. 
Pressure not to exceed 1000 PSI)
Liquid-Filled 
Pressure Gauge
Outlet
To Misting Feed Line
Automatic 
Drain Valve
Oil Filler/Breather Cap
Oil Sight Glass
Oil Drain
On/Off Switch
Power Cord
Water Inlet
Filter Bowl
With Replaceable 5-Micron Filter Element
LIST OF ALL ENCLOSED PARTS
 QTY  PART NO  DESCRIPTION
  1  60100K  Direct-Drive Pump
  1 
56402  Flexible Nylon Tubing 25' Roll
  1 
52000  Automatic Drain Valve
57020 MAINTENANCE KIT
 QTY  PART NO  DESCRIPTION
  1 
57011  Filter Element
  1 
57025  Pump Oil
•  WARNING: Before plugging in the unit for the fi rst time, read the following section carefully. To reduce the risk of 
electric shock. Plug in supplied grounded cord into a properly grounded receptacle. When servicing this unit, unplug 
power cord before attempting any service or repairs.
•  Install pump above grade level on a pre-formed concrete pad, 16"×16" minimum size. 
•  Plug power cord of unit into a properly grounded receptacle.
•  Connect water line to water inlet connector.
•  Unit is pre-fi lled with oil and ready to run. Oil should be half full on the sight glass when unit is off. Do not overfi ll.
•  On new misting systems, fl ush lines before installing nozzles. The pump will not build pressure until all nozzles are installed. 
•  Do not exceed 1000 PSI and do not run pump without water.
•  Winter shutdown: Unplug pump power cord, shut off water supply, remove fi lter bowl and drain water. Also drain water out of all lines, to 
prevent damage to pump or lines.
•  25 feet or more of nylon tubing is recommended in order to reduce vibration noise.
ANNUAL MAINTENANCE INSTRUCTIONS
•  Change oil every 500 hours of runtime or once a year. Use approved Pump Oil (52025). Oil should be half full on the sight glass when 
unit is off. Do not overfi ll.
•  Change Filter Element Annually
INSTALLATION INSTRUCTIONS
DIRECT DRIVE PUMP SPECIFICATIONS
MODEL  FLOW  VOLTS  MOTOR  PUMP  LOAD 
DIMENSIONS
 
GPM 
60 Hz 
HP 
RPM 
Amps 
L x W x H
60100K 
1.0 
120 
0.75 
1725 
10.4 
24x15x13
Maximum pressure is 1000 PSI, normal operating pressure is 800-1000 PSI.
RECOMMENDED MIN-MAX NOZZLE RANGE
 
NOZZLES 
NOZZLES 
NOZZLES 
Nozzle Size 
.014 
.012 
.008
Nozzle Range 
12–25 
15–30 
22–45
Choose .012/.014 nozzles for dry climates and .008 for more humid climates.