Channel Calibration
The next step is to adjust the output level of each channel so that they are 
properly matched. This must be done to insure a correct presentation of multi-
channel sound sources. The adjustment must be as precise as possible, and is 
almost impossible to accomplish by ear. Therefore, we recommend that you 
use a Sound Level Meter. This device insures that all loudspeaker levels are 
precisely matched and set accurately. (The Radio Shack Analog Sound level 
Meter is inexpensive and suitable for this task.)
NOTE: If for any reason you are not sure that you can accomplish 
this calibration task or have any doubts as to how it should be done, 
please contact Outlaw Audio’s technical support BEFORE attempting 
this process. 
Set the meter to Slow response and “C” weighting. Set it to the 70 or 80dB 
sensitivity scale. Position the meter at the approximate center of your listening 
area, at average ear height [approximately 40-46 inches (102-117 cm)] with 
its microphone positioned vertically (pointing at the ceiling). Don’t aim the 
microphone at the speakers, as this will produce inaccurate results.
To proceed with the adjustments, you will access the Channel Calibration 
menu shown below.
Figure 3
CHANNEL CALIB
> LEFT FRONT  :  0dB
  CENTER FRONT :  0dB
  RIGHT FRONT  :  0dB
  RIGHT SURR  :  0dB
  RIGHT BACK  :  0dB
  LEFT BACK  :  0dB
  LEFT SURR  :  0dB
  SUBWOOFER  :  0dB
  RETURN TO MAIN MENU
With no source playing, set the volume level of the Model 950, using the main 
volume control, to 0dB.
To set the channel levels for you system:
1.
  Press the MENU button to enter the Main Menu.
The Main Menu appears on the Front Panel Display and the OSD. The 
cursor on the OSD should be pointing to the Input Configuration menu 
and 
INPUT CONFIG
 appears on the Front Panel Display.
2.  Press the   button until the Channel Calibration menu is selected.
The cursor on the OSD should be pointing to the Channel Calibration 
menu and 
CHANNEL CALIB
 appears on the Front Panel Display.
3.  Press SELECT to enter the Channel Calibration menu.
The Channel Calibration menu appears on the Front Panel Display and the 
OSD (see figure 3).  The selected menu item should be 
LEFT FRONT
.
A special test tone will be generated allowing you to measure the output 
of the speaker that’s playing. 
Note: If the test tone is too loud with the main volume level set 
at 0dB reset it to –10dB and proceed with the calibration as 
described.
4.  Use the < and > buttons to adjust the speaker level.
You can adjust the selected channel level in 1dB steps across a range 
of -15dB to +10dB. The recommended calibration level is 75dB/SPL as 
displayed on the meter.
5.  Press the   button when you have finished making the Left Front 
level adjustment.
Repeat steps 5 and 6 until you have completed setting the level for each 
speaker in your system. Set all the levels to 75dB.
6.  When you have finished adjusting the level for all the speakers in 
your system, press the   button to select the Return to Main Menu 
option.
7.  Press the SELECT or MENU button to return to the Main Menu, or 
press the MENU button twice to exit. 
You can also perform this calibration at any time by using the built in test 
tone, by pressing the TEST button the front panel of the Model 950 or the 
remote control.
To set channel levels using the Test Tone function:
1.
  Press the TEST TONE button on the front panel or TEST button on 
the remote.
This will produce a display that shows:
TEST TONE
LEFT FRONT  :  0dB
When you select this function, the Model 950’s Test Tone will automati-
cally cycle every few seconds through all the speakers you have told the 
Model 950 are connected to the system.
The unit cycles through the speakers in the following sequence:
LEFT FRONTCENTER FRONTRIGHT FRONT RIGHT 
SURR(OUND)RIGHT BACK (SURROUND)LEFT BACK 
(SURROUND)LEFT SURR(OUND)SUBWOOFER
2.  Use the < and > buttons to adjust the speaker level.
You can adjust the selected channel level in 1dB steps across a range 
of -15dB to +10dB.
While you are adjusting each speaker, the Test Tone will remain on that 
channel until you have stopped changing the volume for a few seconds. 
The unit will then resume cycling the Test Tone from speaker to speaker, 
until you touch the TEST TONE button again.
NOTE: Speakers that you selected “None” for in the Speaker Config 
menu will not appear.
3.  Press the TEST TONE button on the front panel or the TEST button 
on the remote control again to exit the Test Tone function.