 208 
Field Weakening 
Field weakening consists of decreasing the stator current component (lowering the magnetization current 
Ixx77)  in  order  to  allow  AC  induction  motors  to  achieve  speeds  superior  to  the  specified  base  speed 
(name plate). The lower the magnetization current, the higher is the speed that can be achieved.  
 
Mag Current
Ixx77
Voltage/ 
Speed
(RPM)
Base 
Speed
Nominal Field 
Weakening
Nominal, at full motor voltage (230V)
208 VAC bus, Higher Ixx77
208 VAC bus, Optimized Ixx77
208 VAC bus, Lower Ixx77
Max Speed(s)
Before Field 
weakening
 
 
Field  weakening  can  be  set  up  experimentally  with  the  goal  of  finding  the  “lowest”  minimum  value  of 
Ixx77  which  allows  the  motor  to  run  at  the  user’s  desired  top  speed,  without  exceeding  the  maximum 
motor specified speed (i.e. bearings, overheating limitations).  
 
The magnetization current Ixx77 can then be adjusted on the fly depending on the commanded speed, rpm 
range  scheduling  in  a  background  PLC  for  example,  to  provide  good  torque  for  positioning  (e.g.  rigid 
tapping) at lower speeds, and allow high speed operation (e.g. for cutting) at the same time. In most cases, 
the slip gain Ixx78 need not be changed.