J1: Main Bus Power Input 
J1 is used to bring the main AC/DC bus power into the Geo Brick Drive. 
 
  J1: Molex 4-pin Male 
Mating: Molex 4-pin Female 
L3
L2
L1
GND
DATA SYSTEMS, 
INC.
 
DELTA TAU 
B 
 
 
Pin # 
Symbol 
Function 
Three Phase 
Single Phase 
DC 
GND 
Ground 
L1 
Input 
AC Line Phase 1 
Not Connected 
Not Connected 
L2 
Input 
AC Line Phase 2 
Neutral 
DC- Return 
L3 
Input 
AC Line Phase 3 
Line 
DC+ 
 
 
 
 
 
 
Molex Mating Connector p/n: 0428160412 
Molex Pins p/n : 0428150031 
Molex Crimper Tool p/n: 63811-1500 
 
Delta Tau Mating Connector p/n: 014-H00F04-049 (for internal use)  
Delta Tau Pins p/n: 014-042815-031 (for internal use) 
 
 
Note 
In single phase operation, use L2 and L3, and leave L1 floating. 
In  DC  mode  operation,  use  L3  for  DC+  and  L2  for  DC  return,  and 
leave L1 floating.