Справочник Пользователя для DCS ANALOGUE TO DIGITAL CONVERTER dCS 904

Скачать
Страница из 86
dCS 904 User Manual
 Manual for Software Version 1.5x and 1.36
dCS Ltd 
June 2000
Manual part no: DOC135904 iss 2B2
Page 44
135904ma2b2.pdf file available from website
Contact 
dCS
 on + 44 1799 531 999 
email to: more@dcsltd.co.uk
(inside the UK replace + 44 with 0)
web site: www.dcsltd.co.uk
Digital Interface Specifications
AES/EBU (AES3)
Input
Output
Type
Balanced, differential
Impedance
110
110
Ω
Sensitivity (unloaded)
1 ~ 10
> 5
V pk-pk
Maximum Wordlength
24
24
bits
Damage level
> 20
V pk-pk
Connector
XLR3 female
XLR3 male
Pin 1
Ground or shield
Pin 2
+Signal
Connections
Pin 3
-Signal
Table 6 – AES/EBU i/o specifications
SDIF-2, SDIF-3 and
DSD
Input
Output
Type
Single ended, ground
referred
Impedance
100
25
Ω
Sensitivity (unloaded)
TTL
TTL
Maximum Wordlength
24
24
bits
Damage level
> 10
V pk-pk
Time skew
  Wordclock in / out
< 50
ns
Connector
BNC x 1
BNC x 3
CH1 (left)
CH2 (right)
Connections
Wordclock In & Out
Table 7 – SDIF-2, SDIF-3 and DSD i/o specifications
Remote control interface
Input / Output
Type
RS-232
Level
RS-232
Baud Rates
1200, 2400, 4800
Data Format
Connector
9 way D type male
Table 8 – Remote Control Interface Details