TROUBLESHOOTING CONT.
D-250 98828  04/08/03
10
Solution hose
Corrosion on fittings
Clean with steel wool. 
fitting hard to
      
   
Soak in acetic acid (white vinegar).
connect
Lubricate lightly with silicone base
lubricant.
Carpet not
Severe soil conditions
Make several passes at right angles to
getting clean.
other.  Use a prespray.
Carpet too wet
Over saturation
Adjust solution pressure to lower setting.
Make several passes without spray.
Carpet browning
Leaving carpet too wet       
Check for loss of vac pressure.
Too much chemical in
Check label for correct solution
concentration.
.
Solution not 
Solution hose connection
Check for positive connection
flowing properly
 
Faulty pump
Repair or replace.
Faulty floor tool valve
Repair or replace.
Faulty  pump switch
Repair.