CENTRAL STATION OPERATION 
 
When an alarm occurs, the communicator first sends the appropriate report to the central station.  After the transmission of the alarm 
to the central station, the operator can talk and listen to people and sounds at the premises.  
 
After the report is received by the central station operator, the Two-Way Audio Module is switched on.  The central station operator 
can now listen to the premises.  The module is always first switched on in the listen mode.  The operator can control the direction of 
the communication by using the Touch-Tones on a telephone.  Each time the operator switches between the listen and the talk mode, a 
short tone will sound over the audio speaker at the subscriber's premises.  This alerts the subscriber that the operator has switched 
communication mode.  If no tones are detected within 90 seconds, the module will disconnect from the phone line. 
 
PRESS 2 FOR CENTRAL STATION TO TALK TO THE PREMISES 
 
PRESS 8 FOR CENTRAL STATION TO LISTEN TO THE PREMISES 
 
PRESS 4 TO DISCONNECT (HANG UP) THE PHONE LINE 
 
When the Two-Way Audio Module is switched on after an alarm transmission, the siren is automatically switched off so the central 
station can listen and talk to the premises.
 
 
PAGING AND LISTENING
 
 
By accessing the telephone menu, you can use an inside or remote phone to talk (page) and listen to someone on the premises.   
 
1)  From the main telephone menu choose the 8 (PHONE). 
2)  To talk or listen to the premises, press the 3 (INTERIOR). 
3)  To talk to someone at the premises, press the 2 key. 
4)  To listen to the premises, press the 8 key. 
 
• 
If no key is pressed, the system will automatically switch to listen mode.   
• 
When complete, press * to return to the main telephone menu. 
• 
If no tones are detected within 90 seconds, the module will switch off and you will return to the main telephone menu. 
 
ANNUNCIATION OF ALARM 
 
The Voice Alarm Module enables the system to speak the type of alarm and zone over a speaker on premises.  When an alarm first 
occurs, the siren is activated.  After a few seconds, the siren is turned off and the type of alarm is announced.  The siren is then 
reactivated.  After a few seconds, the siren is again turned off and the violated zone is announced.  The siren is then reactivated.  This 
process is repeated until the alarm is disarmed or reset. 
 
Note:  During central station communication (while the system is reporting an alarm to the central station), voice alarm notifications 
are temporarily suspended.  After the successful transmission of the alarm to the central station, voice alarm notifications are restarted. 
 
SPEAKER VOLUME CONTROL
 
 
The volume of the audio can be controlled by adjusting a variable resistor on the module.  Use a small screwdriver to adjust R35 
labeled “Speaker Volume”.  Do not adjust R59 labeled “Audio Cancel”.  This variable resistor it is adjusted at the factory to its 
optimal setting. 
 
SPECIFICATIONS 
 
DIMENSIONS: 
   
 
5.5" x 3.25" 
OPERATING VOLTAGE: 
 
6 to 14 VDC 
OPERATING CURRENT:  
 
500 mA maximum 
SPEAKER IMPEDANCE:  
 
Ω 
AGC RANGE: 
   
 
-22 dbm to +10 dbm 
 
REQUIRED MICROPHONE TYPE: 
Condenser w/ built-in preamp