STATUS
DISPLAY
ERROR 
LIGHT
SUGGESTED ACTION
FP
Freeze Protection Engaged.  The  room temperature 
measured by the wireless remote thermostat or indoor 
ambient thermistor active sensor falls below 40°F.
Y
N
No Action required. This setting will disengage 
when the room temperature rises above 43°F.
Fd
Front Desk switch is closed. All outputs are switched off.
Y
N
Open front desk switch to allow occupant unit 
operation.
Fb
Low Remote Battery Warning.
N
Y
Replace Battery in Wireless Devices.
Indoor Ambient Thermistor reads outside the range -20°F 
to 200°F & the wireless thermostat is not communicating 
to the unit control or
Indoor Ambient Thermistor (IAT) without a wireless remote 
thermostat reads outside the range -20°F to 200°F.
F4
Indoor Coil Thermistor either above or below operating 
tolerances.
N
Y
Replace Red Indoor Coil Thremistor .
F5
Wireless Thermostat failure.
N
Y
Replace Wireless Thermostat.
F6
Indoor Discharge Thermistor either above or below 
operating tolerances.
N
Y
Replace Yellow Indoor
Discharge Thermistor.
L6
Discharge Air Too Hot..  
N
Y
Clean Filter or Remove Air Blockage.
L8
Air Restriction in Heating.
N
Y
Clean Filter or Evaporator Coil.
L9
Air Restriction in Cooling.
N
Y
Clean Filter or Evaporator Coil.
LC
Outdoor Coil Thermistor temperature high.
N
Y
Clean Condensor Coils, Check Fan
fault code. Code will reset after cleaning.
C1
Clean Indoor Coil / Filter.
N
Y
Check for Blocked Indoor Air.
C0
Clean Outdoor Coil.
N
Y
Check for Blocked Outdoor Air.
CODE
M
O
D
E
S
A
I
R
F
L
O
W
 
W
A
R
N
I
N
G
S
Replace black Indoor Ambient Thermistor or 
Wireless Remote Thermostat.
Y
Y
F
A
I
L
U
R
E
S
F1
Diagnostic Codes