Cabinet/Countertop Dimensions (cont.)
Installation Requirements
Cutout tolerances +1/16” (+1.6 mm) -0 unless otherwise noted
Non-combustible 
rear wall, rear of 
mounting platform
10” (25.4 cm) min. 
to combustible wall 
above countertop, 
both sides
Cabinet face 
below countertop 
overhang
Increase countertop and overhang  
additional 2 1/2” (6.4 cm) min. for 
combustible rear wall  above 
countertop
3/8” (1.3 cm) 
countertop overhang
Hole 1/2” dia. (1.3 cm), 
2 places, through platform
for hold down bolts 
Gas/electrical utility cut-out in right rear corner of 
mounting platform 8” W X 6” D (20.3 cm X 15.2 cm),
if gas and electrical are routed through bottom
1/2” (1.3 cm) 
countertop 
overhang
1” (2.5 cm) thick mounting platform min.
Countertop
Countertop
1/2” (1.3 cm) 
countertop 
overhang
2” (5.1 cm)
Counterop 
overhang
1” (2.5 cm) 
typical
1 3/8” 
(3.5 cm) 
max.
11 7/16” 
(29.1 cm)
24”
(63.5 cm)
min. 
cabinet 
depth
CL
D
D
B
CL
CL
CL
Rangetop 
Model
B - Cutout 
Width
D - Hole 
Offset
E - Downdraft 
Vent Cutout
Approved Downdraft 
Vent Models
DYRTP366
36” 
(91.4 cm)
16 5/8” 
(42.2 cm)
33 1/2” 
(85.1 cm)
ERV36, ERV3615, 
PRV36
DYRTP486
48” 
(121.9 cm)
20 13/16” 
(52.9 cm)
43 1/2” 
(110.5 cm)
ERV48, PRV48
Cabinet/Countertop Cutout Dimensions without Downdraft Vent - Top View
Installed Rangetop - Side View
Gas connection and power cord may be 
routed through bottom or back of chassis
Gas and electrical connections at 
right rear section of chassis
Cabinet 
face
Installed control 
panel overhang 
1/3/8” (3.5 cm)
24” (61.0 cm)
Countertop
Mounting platform
IMPORTANT: Use only the downdraft vent models specified.