6 Step Ladder Instructions
6.2 STL
100
FXCPU Structured Programming Manual
[Basic & Applied Instruction]
6.2
STL
Outline
In programs using step ladder instructions, a state relay State S is assigned to each process based on
machine operations, and input condition and output control are programmed as sequences connected to the
state output.
machine operations, and input condition and output control are programmed as sequences connected to the
state output.
STL instruction for step ladder programs is expressed as follows in each language.
1. Format and operation, execution form
2. Set data
3. Applicable devices
4. Caution
Refer to the cautions in the items below for expressing step ladders in a structured project (Structured ladder/
FBD, ST).
FBD, ST).
→ Section 6.3 RET
FX
3U(C)
FX
3G(C)
FX
3S
FX
2N(C)
FX
1N(C)
FX
1S
FX
U
/FX
2C
FX
0N
FX
0(S)
Instruction
name
Operation
Execution
form
Expression in each language
Structured ladder/FBD
ST
STL
16 bits
Continuous
STL(EN,s);
Variable
Description
Data type
Input
variable
variable
EN
Execution condition
Always TRUE
Output
variable
variable
Target device or variable
Bit
ENO
Execution state
Bit
Operand
type
Bit Devices
Word Devices
Others
System User
Digit Specification
System
User
Special
Unit
Index
Constant
Real
Number
Character
String
Pointer
X Y M T C S D
.b KnX KnY KnM KnS T C D R U
\G
V Z Modifier K
H
E
"
"
P
z
STL
EN
s
s
ENO