Справочник Пользователя для Mitsubishi Electronics FXCPU
23 Applied Instructions (Extension Function)
23.2 EXTR_OUT / External ROM function
579
FXCPU Structured Programming Manual
[Basic & Applied Instruction]
21
Appl
ied
ied
In
stru
cti
cti
ons
(R
eal
T
T
im
e
C
lock
Contr
Contr
ol)
22
Ap
plied
Instru
ctio
ns
Instru
ctio
ns
(E
xt
er
na
l De
vi
vi
ce
)
23
App
lied Instr
lied Instr
ucti
ons
(Ex
tensi
on
tensi
on
Functi
on)
24
Ap
pl
ied In
struct
struct
ions
(O
thers)
25
Appl
ied
ied
Instru
cti
cti
ons
(B
lock
Dat
a
Dat
a
O
per
at
io
n)
26
App
lie
lie
d Instr
uction
s
s
(Charac
ter
Stri
ng C
ontrol
)
27
Ap
pl
ied Inst
ruct
io
io
ns
(D
ata
Op
eration 3
eration 3
)
28
Appl
ied
ied
In
stru
cti
cti
ons
(D
ata C
om
om
par
ison
)
29
App
lie
lie
d Instr
uction
s
s
(D
ata
T
T
abl
e
O
peration
)
30
Appli
ed In
struc
tions
ed In
struc
tions
(E
xt
ernal Devi
ce
Comm
uni
cat
ion)
23.2
EXTR_OUT / External ROM function
Outline
This instruction is for the short mail transmission of the memory for extension function, inverter operation
monitoring instruction, and parameter readout.
monitoring instruction, and parameter readout.
1. Format and operation, execution form
2. Set data
3. Applicable devices
FX
3U(C)
FX
3G(C)
FX
3S
FX
2N(C)
FX
1N(C)
FX
1S
FX
U
/FX
2C
FX
0N
FX
0(S)
Instruction
name
Operation
Execution
form
Expression in each language
Structured ladder/FBD
ST
EXTR_OUT
16 bits
Continuous
EXTR_OUT(EN,s,sd1,sd2,sd3);
EXTRP_OUT
16 bits
Pulse
EXTRP_OUT(EN,s,sd1,sd2,sd3);
Variable
Description
Data type
Input
variable
variable
EN
Execution condition
Bit
Function number
•
•
K0: Short mail transmission
•
K10: Inverter operation monitoring instruction
•
K12: Inverter parameter readout
ANY16
•
When transmitting short mail:
Mail center, phone number of transmission destination and waiting time
Mail center, phone number of transmission destination and waiting time
•
When issuing inverter operation monitoring instruction and reading
parameter:
Inverter station number
parameter:
Inverter station number
ANY
•
When transmitting short mail:
Transmission message format and message text
Transmission message format and message text
•
When issuing inverter operation monitoring instruction: inverter
instruction code (hexadecimal)
instruction code (hexadecimal)
•
When reading inverter parameter:
Inverter parameter number (decimal)
Inverter parameter number (decimal)
ANY
Output
variable
variable
ENO
Execution state
Bit
•
When transmitting short mail: operation status
•
When issuing inverter operation monitoring instruction and reading
parameter:
Destination device storing readout value
parameter:
Destination device storing readout value
ANY
Operand
type
Bit Devices
Word Devices
Others
System user
Digit specification
System
user
Special
unit
Index
Cons
tant
Real
Number
Character
String
Pointer
X Y M T C S D
.b KnX KnY KnM KnS T C D R U
\G
V Z Modifier K H
E
"
"
P
z z
z z z
z
z
z
z
z z z z
z z
z
z z
z z z
z
z
z
z
z z z z
z z
z
z z
z z z
z
z
z
z
z z z z
z z
z
z z
EXTR_OUT
EN
s
sd1
s
sd1
ENO
sd2
sd3
EXTRP_OUT
EN
s
sd1
s
sd1
ENO
sd2
sd3