30 Applied Instructions (External Device Communication)
30.1 IVCK / Inverter Status Check
708
FXCPU Structured Programming Manual
[Basic & Applied Instruction]
30.1
IVCK / Inverter Status Check
Outline
This instruction reads the operation status of an inverter to a PLC using the computer link operation function
of the inverter. Applicable inverters vary depending on the version.
This instruction corresponds to the EXTR (K10) instruction in the FX
2N
 and FX
2NC
 series.
→ For detailed explanation of the instruction, refer to the Data Communication Edition manual.
1. Format and operation, execution form
2. Set data
*1.
"ch2" is not available for use for the FX
3S
 and FX
3G
 (14-point and 24-point type) PLCs.
3. Applicable devices
S: Refer to "Cautions".
FX
3U(C)
FX
3G(C)
FX
3S
FX
2N(C)
FX
1N(C)
FX
1S
FX
U
/FX
2C
FX
0N
FX
0(S)
Instruction 
name
Operation
Execution 
form
Expression in each language
Structured ladder/FBD
ST
IVCK
16 bits
Continuous
IVCK(EN,s1,s2,n,d);
Variable
Description
Data type
Input 
variable
EN
Execution condition
Bit
Inverter station number
ANY16
Inverter instruction code
ANY16
Channel to be used (K1:ch1,K2:ch2
*1
)
ANY16
Output
variable
ENO
Execution state
Bit
Device storing the read value
ANY16
Operand 
type
Bit Devices
Word Devices
Others
System user
Digit specification
System 
user
Special 
unit
Index
Cons
tant
Real 
Number
Character 
String
Pointer
X Y M T C S D
.b KnX KnY KnM KnS T C D R U
\G
V Z Modifier K H
E
"
"
P
z
S1
S2
z
z z
z
S1
S2
z
z z
z z
z
z
z
z
S1
S2
z
IVCK
EN
ENO
d
s1
s2
n