Справочник Пользователя для Vermont Casting RADVTBD

Скачать
Страница из 52
36
36
Radiance Direct Vent Gas Heater 
20012697
Conversion Precautions
Before proceeding, turn control knob on valve to OFF 
and turn gas supply OFF. Turn OFF any electricity that 
may be going to the appliance.
Fuel Conversion Instructions
WARNING! This conversion kit shall be installed 
by a qualified service agency in accordance with 
the manufacturer’s instructions and all applicable 
codes and requirements of the authority having 
jurisdiction. If the information in these instruc-
tions is not followed exactly, a fire, explosion 
or production of carbon monoxide may result 
causing property damage, personal injury or loss 
of life. The qualified service agency is respon-
sible for the proper installation of this kit. The 
installation is not proper and complete until the 
operation of the converted appliance is checked 
as specified in the manufacturer’s instructions 
supplied with the kit.
CAUTION: The gas supply shall be shut off prior 
to disconnecting the electrical power, before pro-
ceeding with the conversion.
ST226
attach gas line
12/8/99   djt
PILO
T
O
N
OFF
PILO
T
AD
J
LO
HI
Main 
Gas Line
Gas Supply Inlet
ST226a
Fig. 60  Attach the gas line to the right side of the valve.
Conversion Procedure
1.  Remove stove front. Lift stove front up and then 
swing bottom out and away to disengage from the 
stove body. (Page 25, Fig. 46)
2.  Undo the right and left latches at the top of the glass 
frame. (Page 25, Fig. 47)
3.  Pull the top edge of the glass and frame assembly 
away from the firebox face. Place the assembly out 
of the way on a flat, padded surface such as a coun-
ter protected by a towel.
4.  Remove the logset from the firebox.
Valve Conversion
RADVT Series Models
1.  Turn control knob to the OFF position, and shut off 
the gas supply to the valve.
2.  Allow the valve 
to cool to room 
temperature.
3.  Remove the 
black protection 
cap by hand. 
(Fig. 61)
4.  Insert a 5/32” 
or 4 mm Allen 
wrench into 
the hexagonal 
key-way of the 
screw (Fig. 62), 
rotate it counter-
clockwise until it 
is free and extract 
it.
5.  Check that the 
screw is clean 
and if necessary 
remove dirt.
6.  Flip the screw. 
(Fig. 63)
7.  Using the Allen 
wrench as shown 
in Figure 64, 
rotate the screw 
clockwise and 
tighten until snug.
WARNING: Do not overtighten the 
screw. Recommended to grip the wrench by the 
short side.
8.  Verify that if the conversion is from NG to LP, the 
screw must be reassembled with the red o-ring vis-
ible. (Fig. 65)
��
�����
������������
����
Figure 61
��
��
�����
������������
����
Figure 
62
��
��
�����
����������
����
Figure 63
��
��
�����
������������
����
Figure 64
��
��
��
��
LP Configuration
Natural Gas
Configuration
CO141
O-ring configuration
6/07
Red O-ring Visible
Red O-ring NOT Visible
CO141
Figure 65
9.  Replace the black protection cap.
WARNING: Check that also the pilot and 
main burner injectors are appropriate for 
the gas type.
RADVTC Series Models
1.  Follow procedure for pilot type 2 to replace pilot 
orifice.