Справочник Пользователя для Standard Horizon CPV550

Скачать
Страница из 148
Page 22
CPV550
2.7
FF520 FISH FINDER SETUP
When a FF520 is connected to the GPS Chart Plotter:
a. The Gray and white wires cannot be used to connect to external NMEA devices.
b. Port 2 of the NMEA in/out Communication setup menu must be changed so the GPS
Chart Plotter can communicate with the FF520.
1. From the Chart page, press [MENU]. Move the ShuttlePoint knob to highlight SETUP
MENU and press [ENT].
2. Move the ShuttlePoint knob to highlight ADVANCED SETUP and press the [ENT] key.
3. Move the ShuttlePoint knob to highlight IN/OUT CONNECTIONS and press the [ENT]
key.
4. Move the ShuttlePoint knob to highlight PORT2 INPUT and press the [ENT] key.
5. Move the ShuttlePoint knob up/down to select FF520 and press the [ENT] key. Press
[CLR] or move the ShuttlePoint knob to the left until the Chart page is shown.
 
Figure 2.7 IN/OUT CONNECTION menu
2.7.0 AUX Connector Table
Pin Wire Color Description
Connection Example
Additional Information
 1
Black
NMEA Common
Common for NMEA devices
 2
Red
---
No Connection
 3
Green
NMEA Common
Common for NMEA devices
 4
Blue
---
No Connection
 5
Brown
---
No Connection
 6
Gray
NMEA Input Port 4
Conncect to output of NMEA device Default is NMEA0183
 7
White
NMEA Output Port 4
Conncect to intput of NMEA device
Default is NMEA0183 with GLL. RMB, RMC, and XTE sentences
 8
Yellow
---
No Connection