Справочник Пользователя для Ingersoll-Rand 612058E

Скачать
Страница из 4
OPERATOR’S MANUAL
612058–E
RELEASED: 8–15–95
IPP/PSE
INCLUDING:ĂSERVICE KITS, GENERAL DESCRIPTION & TROUBLESHOOTING
ALSOINCLUDE MANUALS: 6641X-X AIR MOTOR MANUAL, FORM 3637-2GENERALINĆ
FORMATION SHEET.
 PUMP
3” AIR MOTOR
5:1 RATIO
2 1/4” STROKE
612058–E
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
SERVICE KITS
Use only genuine AROR replacement parts to assure compatible
pressure rating and longest service life.
637066-B for repair of Air Motor section.
GENERAL DESCRIPTION
This model is designed for high volume delivery of low viscosity fluids
such as motor oil, gear oil or transmission fluids. Material dispensing
accessories and supply lines and fittings must be capable of withstandĆ
ing pressures developed by pump.
The ARO 5:1 ratio basic pump assembly consists of a 3" air motor
and ball check lower pump end.
The ball check design provides for easy priming of the lower foot
valve. Material is delivered to the pump discharge outlet on both
the up and down stroke.
RATIO x REGULATED AIR PRESSURE TO AIR MOTOR = MAXIMUM FLUID
PRESSURE.
The 5:1 ratio is an expression of the relationship between the air
motor area and the lower pump end area. When 150 p.s.i. (10 bar)
air pressure is supplied to the air motor, the lower pump end will
develop a maximum of 786 p.s.i. (54 bar) fluid pressure (at no flow)
- as the fluid control is opened, the flow rate will increase as the air
motor cycle rate increases to keep up with the demand.
Air Motor
FIGURE 1
66419
25 5/16
15 11/16”
(643 mm)
(398.4 mm)
1/2 NPT
Mat’l Outlet
1 1/2 NPT
Mat’l Inlet
Lower Pump
Air Inlet
2608
Connector
INCLUDED BUT NOT
SHOWN: 210 COUPLER
F022
OPERATING AND SAFETY PRECAUTIONS
HEED ALL WARNINGS.
DO NOT EXCEED MAXIMUM WORKING PRESSURE OF 786 PSI (54
BAR) AT 150 PSI (10 BAR) AIR INLET PRESSURE.
 WARNING
: HIGH PRESSURE DEVICE. Improper usage of
this equipment could result in serious injury. The possibility
of injection into the flesh is a potential hazard. Never allow any
part of the human body to come in front of or in direct contact
with the material outlet. An injection injury can be serious. If
injection should occur, contact a qualified physician immediĆ
ately for treatment.
COMPONENTRUPTURE.Thispumpiscapableofproducinghighmaterial
pressure as stated on pump model plate.
Be sure material hoses and other components are able to withstand fluid
pressures developed by this pump.
Donotoperatepumpcontinuouslyatspeedsinexcessof75cyclesperminĆ
ute.
Disconnectair line from pump air motor when system sits idle for long periĆ
ods of time.
Materialsandsolventsbeingpumpedbythispumpmustbecompatiblewith
the parts of this pump that come in contact with the material and solvent.
 WARNING
: PREVENT STATIC SPARKING. If static sparking
occurs, fire or explosion could result. Pump, dispensing
valve and containers must be grounded when handling inĆ
flammable fluids such as petroleum products, paints, lacĆ
quers, etc. and wherever discharge of static electricity is a
hazard.
Usegrounded hoses (static wire) and be sure the object is grounded if it can
produce a static charge.
THE ARO CORPORATION 
D
 ONE ARO CENTER 
D
 BRYAN, OHIO 43506–0151
E
1995 THE ARO CORPORATION 
D
 PRINTED IN U.S.A.
&
 (419) 636–4242 
D
 FAX (419) 636–2115