CLEARANCE AND AIR FLOW 
Service Top Cutout Dimensions 
 
Note: See Manual Cover for DO3637R, DO4837R,  
DO3623R & 4823R Service Top Cutout Dimensions. 
 
Clearance Dimensions 
 
The Refrigerated section must maintain airflow clear-
ance.  Dimensions are as follow. 
1. 4" Minimum Spacing from bottom of refrigeration 
frame to bottom of cabinet or floor required for ade-
quate air flow. 
2. 9 1/2" Countertop / Facia enclosure space on cabi-
nets or counter to allow for pullout system slide-out. 
3.  15" Minimum opening in back of cabinet or counter 
(to pull out refrigeration system). 
4. Back of counter / cabinet must be vented at specific 
sizes to allow for proper air intake and air exhaust.  
See Venting Instructions sections for specifics. 
5. Obstruction or restriction of air can void warranty.  
 
Note: See Venting Instructions sections (next two 
pages) for more specific Air Intake and Air Exhaust 
clearance dimensions for Models DO3637R & 
DO4837R.  
9 1/2” (SEE 
NOTE 2) 
15” 
(SEE NOTES 
3 & 4) 
4” (SEE NOTE 1) 
ABOVE ILLUSTRATION APPLIES TO BOTH 
MODELS DO3637R AND DO4837R