5. Using a grounded drill, drill a 
¹⁄₄ in. hole in the cold water pipe 
you have selected.
 
6. Fasten the shutoff valve to the cold water pipe with the pipe 
clamp. Be sure the outlet end is solidly in the 
¹⁄₄ in. drilled hole 
in the water pipe and that the washer is under the pipe clamp. 
Tighten the packing nut. Tighten the pipe clamp screws 
carefully and evenly so washer makes a watertight seal. Do 
not overtighten or you may crush the copper tubing. 
7. Slip the compression sleeve and compression nut on the 
copper tubing as shown. Insert the end of the tubing into the 
outlet end squarely as far as it will go. Screw compression nut 
onto outlet end with adjustable wrench. Do not overtighten. 
8. Place the free end of the tubing in a container or sink, and 
turn ON the main water supply. Flush the tubing until water is 
clear. Turn OFF the shutoff valve on the water pipe. Coil the 
copper tubing.
9. Route copper tubing to the refrigerator.
Water System Connection
1. Remove the shipping tape from the gray, coiled water tubing 
on the rear of the refrigerator. 
2. Before attaching copper tubing to the refrigerator, flush at 
least 2 quarts (1.9 L) of water through the copper tubing and 
into a bucket to get rid of any particles in the water line. 
3. Check for leaks around the saddle valve. Do not overtighten 
clamp or sleeve. This will crush the copper tubing.
4. Make connection to the refrigerator. 
Style 1 - Connecting to a Water Line:
Additional Parts Needed: Coupling, ferrule and nut. 
Slide the purchased nut, then the purchased ferrule onto the 
tubing. Push the tubing into the purchased coupling as far as 
it will go. Slide the nut and ferrule forward. Tighten the nut by 
hand. Then tighten it with a wrench two more turns. Do not 
overtighten. 
Style 2 - Connecting to a Water Valve: 
NOTE: The water shutoff should be located in the base 
cabinet on either side of the refrigerator. The right-hand side 
is recommended. The access hole through the right cabinet 
must be within 
¹⁄₂ in. (12.7 mm) of rear wall.
Push the bulb end of the tubing into the water valve as far as 
it will go. Slide the nut forward and finger tighten. Tighten the 
nut by hand. Then tighten it with a wrench two more turns. Do 
not overtighten. 
5. Turn shutoff valve ON. 
6. Check for leaks. Tighten any nuts or connections (including 
connections at the valve) that leak.
Plug in Refrigerator
1. Set control switch at top of cabinet to the OFF position. 
2. Plug into a grounded 3 prong outlet. 
1. Cold water pipe
2. Pipe clamp
3. Copper tubing
4. Compression nut
5. Compression sleeve
6. Shutoff valve
7. Packing nut
1. Line to refrigerator
2. Nut (provided)
3. Bulb
4. Coupling (purchased)
5. Ferrule (purchased)
6. Nut (purchased)
1
2
3
4
5
6
1. Bulb
2. Nut (provided)
1
2
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Do not use an extension cord.
Do not use an adapter.
Do not remove ground prong.