6.  Align  the  telescopic  stack  to  the  pre-drill 
holes  on  the  ceiling  and  securely  fasten  to 
the  joists  and  cross  framing  lumber  with 
eight  screws  (not  provided).    Make  sure 
screws  are  driven  into  center  of  joists  and 
cross framing lumber for maximum support. 
7.  Adjust  the  blower  unit  to  the  telescopic 
stack  using  reference  F  calculated  in 
TABLE 1 on page 4 and measurements on 
pages  14-15.    Tighten  blower  unit  to  the 
telescopic stack with four
 
(M5 x 15) screws 
(provided) as shown in Figure 4.
 
 
 
SAFETY WARNING 
RISK  OF  ELECTRICAL  SHOCK.    THIS 
RANGE 
HOOD 
MUST 
BE 
PROPERLY 
GROUNDED.    MAKE  SURE  THIS  IS  DONE 
BY 
QUALIFIED 
ELECTRICIAN 
IN 
ACCORDANCE  WITH  ALL  APPLICABLE 
NATIONAL 
AND 
LOCAL 
ELECTRICAL 
CODES.    BEFORE  CONNECTING  WIRES, 
SWITCH  POWER  OFF  AT  SERVICE  PANEL 
AND  LOCK  SERVICE  PANEL  TO  PREVENT 
POWER  FROM  BEING  SWITCHED  ON 
ACCIDENTALLY. 
8.  Route house wiring into the ceiling as close 
to  the  installation  location  as  possible.  
Allow  additional  length  to  drop  down  from 
the ceiling to the electric box. 
9.  Connect  the  electrical  wires  according  to 
color  (green  to  green,  white  to  white,  and 
green  to  green)  and  cap  with  wire 
connectors  as  shown  in  Figure  5.  Green 
wire  must  be  grounded  to  reduce  risk  of 
electric shock. 
 
 
Ductwork Installation 
 
10. Use  7”  round  aluminum  or  steel  pipe  (not 
provided)  to  connect  the  7”  round  damper 
on the hood to the ductwork above. NOTE: 
Place  7”  round  duct  pipe  over  the  damper.  
Seal with duct tape to make all joints secure 
and  air  tight.    NOTE:  MAKE  SURE  FLAPS 
ON  DAMPER  CAN  OPEN  &  CLOSE 
FREELY. (Figure 6) 
 
 
Figure 4 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 5 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 6 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Telescopic Stack Installation 
Wiring to Power Supply