Instructions for the Installer
 
 
 
 
2.  INSTALLING THE OVEN 
 
 
 
The oven is designed for free-standing installation on a horizontal work-
top. It must be far enough from the wall behind it to allow easy access to 
the terminal board for connection of the power supply lead. Installation 
must be carried out by a 
qualified engineer in compliance with the 
relevant EEC DIRECTIVES. 
 
 
2.1  Electrical connection (Mod.Alfa 200XE) 
 
Check that the power supply voltage and size are as specified on the 
nameplate on the back of the oven. This nameplate must never be 
removed.
 
 
 
 
 
Operation at 380-415V3N~: use a 
H07RN-F five-wire cable (cable of 5 x 
1.5 mm2). 
 
 
 
In case of connection to the electrical mains by means of socket and pin, 
the connection must be completed with a plug of suitable rating. The 
power supply plug and wall socket must be of the same type (in 
compliance with CEI standards). Check that the power supply line is 
properly earthed. The use of reductions, adapters or junctions is not 
recommended. 
 
 
If a permanent connection to the elctrical mains is used, the appliance's 
power supply line must be fitted with an omnipolar breaking device with 
contact breaking gap of at least 3 mm, located in an easily accessible 
position close to the appliance itself. 
 
 
 
 
The power supply socket on the rear of the oven must only be used to 
power the extractor hood supplied as an optional accessory, having 
maximum power absorption of 300W. 
 
 