Справочник Пользователя для Cabletron Systems 8H02-16
Installing the 8H02-16
8H02-16 User’s Guide
3-3
3.4.2
Rackmount Installation
To install the 8H02-16 in a 19-inch rack, Cabletron Systems includes an
accessory kit containing the rackmount brackets, mounting screws, and a
strain-relief bracket for cable management.
accessory kit containing the rackmount brackets, mounting screws, and a
strain-relief bracket for cable management.
Tabletop and shelf installations must be within reach of the network
cabling and meet the requirements listed below:
cabling and meet the requirements listed below:
•
Locate the 8H02-16 within seven feet of an appropriate grounded
power receptacle that meets the power supply requirements listed in
Appendix A, Specifications.
power receptacle that meets the power supply requirements listed in
Appendix A, Specifications.
•
Maintain a temperature of between 5
°
C (41
°
F) and 40
°
C (104
°
F) at
the installation site with fluctuations of less than 10
°
C per hour.
WARNING
Before installing the 8H02-16 into a rack, ensure that the rack
supports the device(s) without compromising the stability of the
rack. Otherwise, personal injury and/or equipment damage
may result.
supports the device(s) without compromising the stability of the
rack. Otherwise, personal injury and/or equipment damage
may result.
!
CAUTION
To ensure proper ventilation and prevent overheating, leave a
minimum clearance space of 5.1 cm (2.0 in) at the left, right
and rear of the 8H02-16.
minimum clearance space of 5.1 cm (2.0 in) at the left, right
and rear of the 8H02-16.