Справочник Пользователя для PioneerPOS G24-L

Скачать
Страница из 444
Chapter 3:  AT Commands Reference
 April 15, 2008
G24-L AT Commands Reference Manual
3-57
The following table shows the +COLP parameters.
Example
AT+COLP=0
OK
AT+COLP=2
+CME ERROR: Numeric parameter out of bounds
+MTTY, Motorola TTY Configuration
This AT command is used to enable or disable TTY (Tele Typewriter) support in G24-L modules.
Note:
Tele-typewriter or Teletype, a typewriter with an electronic communication. TTY is an 
electronic device for text communication via a telephone line, used when one or more of 
the parties have hearing or speech difficulties.
Table 3-31: +COLP Parameters
<Parameter>
Description
<n>
Sets/displays the result code presentation status of the G24-L.
0
Disable (default)
1
Enable
<m>
Displays the subscriber’s COLP service status in the network.
0
COLP not provisioned
1
COLP provisioned
2
Unknown (for example, no network, and so on)
<number>
Sets the phone number, using the format specified by <type>.
<type>
Sets the address octet type in integer format (refer to GSM 04.08 [8] subclause 
10.5.4.7).
129
Unknown
145
International (used when dialing string includes "+" international access code 
character)
<subaddr>
Sets the subaddress, using the format specified by <satype>.
<satype>
Sets the address octet type in integer format (refer to GSM 04.08 [8] subclause 
10.5.4.8).
<alpha>
An optional, string-type, alphanumeric representation of <number> corresponding to 
the entry found in the phonebook. The character set is defined by +CSCS (