Справочник Пользователя для IBM 1400 (2611)

Скачать
Страница из 204
      
 
Symptom/Error
FRU/Action in Sequence
Battery fuel-gauge
doesn't go higher
than 90%.
Ÿ
Remove battery pack and let
it cool for 2 hours.
Ÿ
Refresh battery (continue
using battery until power off,
then charge the battery).
 
Ÿ
Battery pack
 
Ÿ
Charger board
 
Ÿ
System board
System configuration
does not match the
installed devices.
Ÿ
Enter BIOS Utility and
execute "Load Setup Default
Settings"; then reboot the
system.
 
Ÿ
Reconnect hard
disk/diskette/CD-ROM drive
connector.
System hangs
intermittently.
 
Ÿ
Hard disk/diskette/CD-ROM
drive connector
Ÿ
Fan (go to “Running the PQA
Diagnostics Program” on
page  49).
 
Ÿ
System board
 Peripheral-Device-Related Symptom
Symptom/Error
FRU/Action in Sequence
External display does
not work correctly.
Ÿ
Press Fn+F3, LCD/CRT/Both
display switching.
 
Ÿ
System board
Printer problems.
Ÿ
Run printer self-test.
 
Ÿ
Printer driver
 
Ÿ
Printer cable
Ÿ
Ensure that "Parallel Port" in
the "Onboard Devices Config-
uration" menu of the BIOS
Utility is correctly set.
 
Ÿ
System board
Serial or parallel port
device problems.
 
Ÿ
Device driver
 
Ÿ
Device cable
 
Ÿ
Device
Ÿ
Ensure that "Serial Port" and
"Parallel Port" in the
"Onboard Devices Configura-
tion" menu of the BIOS Utility
is correctly set.
 
Ÿ
System board
 Modem-Related Symptoms
44
ThinkPad i Series 1400 HMM