Volumetric flow rate
Section 6: Meter operation
 Reference, Installation, and Operations Manual
June 2013
3-9000-743 Rev S
6.1.9
Volumetric flow rate
The Daniel Mark III Ultrasonic Gas Flow Meter meter provides three volumetric flow rate values: 
raw, (expansion-corrected and/or profile-effect corrected) flow-condition, and base-condition. 
Note that a positive volumetric flow rate indicates flow in the forward direction whereas a 
negative volumetric flow rate indicates flow in the reverse direction.
Raw volumetric flow rate
The “raw” volumetric flow rate is calculated from the average gas flow velocity (wet-calibration 
gas flow velocity) as shown in 
.
Equation 6-12  Raw volumetric flow rate
where
Flow-condition volumetric flow rate
The flow-condition volumetric flow rate is the result of applying expansion correction and flow-
profile correction to the raw volumetric flow rate as shown in 
 subject to the low-
flow cut-off. If the resulting value is below the low-flow cut-off value, it is set to zero. The low-flow 
cut-off volumetric flow rate (
CutRate) is the specified low-flow velocity threshold (ZeroCut) 
converted to a volumetric flow rate.
=
“raw” volumetric flow rate (m
3
/h) (
QMeter)
=
wet-calibration gas flow velocity (m/s) (
AvgFlow)
=
geometric constant, pi (dimensionless) (3.14159...)
=
pipe inside diameter (m) (
PipeDiam)
Q
Raw
V
WetCal
πD
in
2
4
-----------
×
3600
×
s hr
=
Q
Raw
V
WetCal
π
D
in