Справочник Пользователя для Emerson Process Management 3420

Скачать
Страница из 398
 236
Hourly log
Section 6: Meter operation
 Reference, Installation, and Operations Manual
June 2013
3-9000-743 Rev S
6.6.2
Hourly log
The Mark III meter stores an hourly log record once per hour on the hour. The meter can store up 
to 2400 hourly records (100 days’ worth). The user can select whether old, unread records can 
be overwritten by new records when the log becomes full via the data point 
DoOverwriteUn-
readHoulyLog. This point can be modified using the Daniel MeterLink Tools - Edit/Compare 
Configuration
 screen. The default is to overwrite old, unread records. Refer to 
 for 
information on reading records and marking records as read. The data point 
IsHourlyLogFull indicates whether or not the hourly log is full and cannot overwrite old, unread 
records.
The data points included in the hourly log and the corresponding log action are as shown in the 
table below. Data points required by the API Chapter 21 standard are marked with an asterisk 
(*). (Refer to 
 for information on the log action types.) For information on a particular 
data point, consult Daniel MeterLink online help. (There is a help topic for each data point. From 
Daniel MeterLink, click on Help, click on Mark III Registers Reference, select the Index tab, 
start typing the data point name until the desired point is highlighted, and then click the 
Display
 button.)
Table 6-19  Hourly log content
Data Point
Log Action
PosVolFlow*
Totalize and Snapshot
NegVolFlow*
Totalize and Snapshot
PosVolBase*
Totalize and Snapshot
NegVolBase*
Totalize and Snapshot
PosEnergy
Totalize
NegEnergy
Totalize
PosMass
Totalize
NegMass
Totalize
FlowTemperature*
Flow-Gated
FlowPressure*
Flow-Gated
AbsFlowPressure*
Flow-Gated
AccumFlowTime*
Totalize
AvgSndVel*
Flow-Gated
CompAvgMeterSndVel
Snapshot (the value is itself an hourly 
average)
CompAvgAGA10SndVel
Snapshot (the value is itself an hourly 
average)