 Reference, Installation, and Operations Manual
Section 6: Meter operation
3-9000-743 Rev S
June 2013
System log
 253
6.6.5
System log
The Mark III meter logs all system messages in the system log. The meter can store up to 100 
system records. The user can select whether old, unread records can be overwritten by new 
records when the log becomes full via the data point 
DoOverwriteUnreadSystemLog. This 
point can be modified using the Daniel MeterLink Tools - Edit/Compare Configuration screen. 
The default is to overwrite old, unread records. Refer to 
 for information on reading 
records and marking records as read. The data point 
IsSystemLogFull indicates whether or not 
the system log is full and cannot overwrite old, unread records.
Repetitive system messages are prevented from filling up the system log. When a particular 
system message occurs 3 times within 60 seconds, that system message is suppressed until that 
message’s frequency drops below the 3 times-per-60 sec rate. The system log records indicate 
when a system message suppression is started and ended.    
6.6.6
Reading log records 
Mark III meter log records are read using the Daniel MeterLink Logs/Reports - Meter Archive 
Logs
 screen. The are three log groups:
daily
hourly
event (audit, alarm, and system logs)
Select the desired log group(s) via the 
Collect daily log/Collect hourly log/Collect event log
 check 
boxes. If the event group is selected, the audit, alarm, and system logs are individually 
selectable. Whenever any log is collected, the current meter configuration is also collected.
Options for reading daily and/or hourly log records
The options for reading daily and hourly log records are the same. The Daniel MeterLink 
Logs/Reports - Meter Archive Logs
 screen indicates the number of days’ records that are 
available to read. Select the log type(s) to be collected via the Collect daily log and/or Collect 
hourly log check boxes. Select whether to collect either all log records or the last specified 
number of days’ records. Also, select whether to collect all log data or just the data points 
required by the API Chapter 21 standard. 
 lists the daily log data points and 
 
lists the hourly log data points. For both tables, data points required by the API Chapter 21 
standard are marked with an asterisk (*).
Options for reading audit, alarm, and/or system log records
The options for reading audit, alarm, and system log records are the same. The Daniel MeterLink 
Logs/Reports - Meter Archive Logs
 screen indicates the number of records available for each 
The System log is for Daniel use and interpretation.
Note that reading log records is an optional feature as described in general in 
and in detail in 
.