Collecting logs and viewing Excel reports
Section 7: Maintenance and troubleshooting
 Reference, Installation, and Operations Manual
June 2013
3-9000-743 Rev S
7.6.1
Collecting logs and viewing Excel reports
To collect Maintenance and Trend Logs for meter diagnostics,
1.
Establish communication with the meter via Daniel CUI.
2.
From Daniel CUI main window, use the 
Logs/Reports|Maintenance Logs and Reports 
menu path. The Maintenance Logs and Reports dialog appears.  
Figure 7-14  Maintenance Logs and Reports Dialog 
3.
Set the log collection Duration (mins) (2 minutes is the default value which is normally 
adequate to capture a good snapshot of the meter's current diagnostic parameters). To 
get a good representation of the meter performance, it is recommended that there be 
at least 30 records (lines of data). The actual number of records collected are a function 
of the type of communication (Serial or Ethernet), Stack Size (if stacking is turned on), 
and the Collection speed selected. The duration value can be changed by clicking the 
number in the display/edit box and entering a new value.
4.
If desired, a comment may be included in the log file by entering it in the display/edit 
box provided.
5.
In the Log Format field, select Microsoft® Excel. DO NOT select Comma Separated 
Values (CSV), as this format is not compatible with the generation of graphics, trending 
and analysis offered by Daniel CUI and Microsoft® Excel. CSV should only be used if the 
computer does not have Microsoft® Excel. Once the file is collected in the CSV format, 
it can not be converted to a Microsoft® Excel format.