 Reference, Installation, and Operations Manual
Upgrading a Mark II to a Mark III
3-9000-743 Rev S
June 2013
Meter electronics upgrade
 299
AI
Appendix C  Upgrading a Mark II to a Mark III
C.1
Meter electronics upgrade
This section describes the important differences between the Daniel Mark II and Mark III meters. 
This section also includes instructions on how to upgrade a Mark II meter to use the Mark III 
electronics using the Daniel MeterLink configuration conversion feature.  
C.2
What’s new In Mark III
The Mark III meter electronics offers many new and improved features over the previous Mark II 
design as discussed below:
F
ASTER
 
UPDATE
 
RATES
. The Mark III uses a newer, faster processor with a double-precision 
hardware floating-point unit. This allows for faster transducer firing rates resulting in 
faster data updates. The Mark III meter offers two update rates: rapid (0.25 sec) and 
standard (1 sec) versus the typical Mark II update rate of about 5 seconds (for a 
SeniorSonic
TM
 meter).
AGA8 D
ETAIL
 
METHOD
. The Mark III meter adds the AGA8 Detail method for calculating 
compressibilities.
O
PTIONAL
 AGA10 
SOUND
 
VELOCITY
 
CALCULATION
 
AND
 
COMPARISON
. The Mark III meter optionally 
calculates the AGA10 sound velocity and compares it on an hourly averaged basis to the 
meter-measured sound velocity.
E
NERGY
 
RATE
 
CALCULATION
. The Mark III meter calculates the energy rate (if the heating value 
is available). The energy rate is available for output on the frequency outputs and optional 
analog output.
M
ASS
 R
ATE
 C
ALCULATION
. The Mark III meter calculates the mass rate if the gas flow-
condition mass density is available (either specified or calculated as part of AGA8). The 
mass rate is available for output on the frequency outputs and optional analog output.
O
PTIONAL
 G
AS
 C
HROMATOGRAPH
 
INTERFACE
. The Mark III meter optionally interfaces to a 
Daniel gas chromatograph via Modbus for retrieving live gas property data. This feature 
requires use of the Option Board.
Daniel CUI version 4.21 is the final version that supports Daniel Mark II Gas Ultrasonic 
meters. If you are communicating with a Daniel Ultrasonic Mark II Gas Flow Meter, you do 
not need to uninstall version 4.21 or earlier versions of Daniel CUI before installing 
MeterLink. Version 4.21 and earlier versions of Daniel CUI should not be run simultaneously 
with MeterLink.