Справочник Пользователя для Maxon Telecom SP200

Скачать
Страница из 95
Maxon SP200/210 Radio SP200/210
TROUBLESHOOTING
Issue 1.0
Page 6-2
03/01
6.2 Troubleshooting Chart
Symptoms
Causes
Remedy
Radio does not work
1.  Battery is discharged
(below 6V =/-10%)
2. Fuse 
blown
3.  5V supply missing
1. Replace 
battery
2. Replace 
Fuse
3.  Check IC5 (5V +/-0.2V)
Warning Tone and
radio does not work
1. PLL 
error
2. EEPROM 
failure
3. Low 
battery
1. Check 
TCXO/VCO/PLL 
IC
freqs programmed
2. Re-program
3.  Replace, or charge, battery
Poor Rx sensitivity
(-10 to –60dBm)
1.  Defective Antenna switch
2. Defective 
front-end
3. Defective 
mixer
4. IF 
IC
5.  VCO output level
6. LO 
frequency
1.  Check D5 & D6
2.  Check front end
3.  Check D9, T1 & T2
4.  Check X1, CF1/CF2 & IC5
5.  Check Rx VCO level >+1.2dBm
6. Retune 
TCXO
Defective Rx
1.  VCO frequency change or drop
in level
2.  Defective voltage source
1. Repair 
VCO
Defective IF IC (IC1)
2. Check 
IC1
PLL Error
1.  Defective 12.8MHz TCXO
2.  Voltage source for Rx VCO / Tx
VCO
3. Defective 
PLL
1. Replace 
TCXO
2.  Check Rx VCO / Tx VCO
3.  Replace IC2.  Check DC/DC
converter
Low / No Tx power
1.  Tx Amp
1.  Check Q9, IC9 & power control
loop
No 
modulation
1. Audio 
ASIC
1. Check 
IC406
No programming
1.  Defective programming lead
2.  Check accessories connector.
Table 6-2 – Troubleshooting chart