Справочник ПользователяСодержание1. Scope41.1. Overview41.2. Applicable model41.3. System configuration42. Names and functions of main parts52.1. Outline view52.1.1. LIU006Z52.1.2. LIU007Z (for VF-FS1)52.2. Diagnostics62.2.1. Service LED62.2.2. Status LED72.2.3. Fault LED72.3. RS485 communication port83. Configurations93.1. Neuron ID93.2. Service pin93.3. Device interface (XIF) file93.4. LNS Plug-in93.5. Inverter configurations93.6. Command & Setpoint selection (Local/Remote)103.7. Reference parameter of the inverter114. Functional profile124.1. Functional profile supported by this option124.2. Object id125. Node Object functional block135.1. Object map135.2. Network variables (Node Object)135.2.1. nciLocation (Location Label)145.2.2. nviRequest (Object Request)145.2.3. nvoStatus (Object Status)156. ACMotorDrive functional block166.1. Object map166.2. Network variable list (VSD_6010_11)176.3. Network variable list (the other)186.4. Configuration properties196.4.1. nciMaxSpeed (Maximum Speed)196.4.2. nciMinSpeed (Minimum Speed)196.4.3. nciRcvHrtBt (Receive Heartbeat Time)206.4.4. nciSndHrtBt (Send Heartbeat Time)206.4.5. nciMinOutTm (Minimum Send Time)206.4.6. nciNmlSpeed (Nominal Motor Speed in min )216.4.7. nciNmlFreq (Nominal Motor Frequency)216.4.8. nciRampUpTm (Ramp Up Time)216.4.9. nciRampDownTm (Ramp Down Time)226.4.10. nciDrvSpeedScale (Default value for nviDrvSpeedScale)226.4.11. nciPwUpOutTm (Power up delay time).226.5. Input network variables236.5.1. nviDrvSpeedStpt (Drive Speed Setpoint)236.5.2. nviDrvSpeedScale (Drive Speed Setpoint Scaling)236.5.3. nviResetFault (Fault Reset Command)236.5.4. nviInvSetFreq (Frequency Setpoint)246.5.5. nviRelay1 /nviDigitalOut1,2 (Control of Digital Output)246.5.6. nviDigitalOutput (Control of All Digital Outputs)246.5.7. nviAnalogOut1,2 (Control of Analog output)256.5.8. nviEmergOverride (Emergency stop)256.5.9. nviParamCmd (Parameter access)266.6. Output network variables276.6.1. Output network variable update276.6.2. nvoDrvCurnt (Drive Output Current)276.6.3. nvoDrvSpeed (Drive Speed Feedback)276.6.4. nvoDrvRunHours (Drive Total Running Hours)276.6.5. nvoInvOutFreq (Frequency Feedback)276.6.6. nvoDrvFeedback (Velocity Feedback)286.6.7. nvoStatusWord (Inverter Status)286.6.8. nvoDrvAlarm (Alarm)286.6.9. nvoAlarmWord (Alarm Status)296.6.10. nvoDrvThermal (Drive Thermal State)296.6.11. nvoMotorThermal (Motor Thermal State)296.6.12. nvoTorque (Motor Torque Monitor)296.6.13. nvoDrvEnergy (Cumulative Input Energy)306.6.14. nvoDigitalInput (All Digital Inputs Monitor)306.6.15. nvoDigitalIn1 to 8 (Digital Input Monitor)306.6.16. nvoAnalogIn1 to 3 (Analog Input Monitor)316.6.17. nvoEmergStatus (Emergency Status)316.6.18. nvoParamResp (Parameter Access Response)326.6.19. nvoTypeVer (Identification)327. Example usage337.1. Procedure337.2. Binding337.3. Option unit reset method337.4. Communication health management347.5. Parameter access method358. Specifications37Размер: 296,5 КБСтраницы: 38Язык: EnglishПросмотреть