Toshiba EM1-31074 用户手册
14-9
14. OPERATING PROCEDURES
14.5 ISSUING LABELS WITH NET WEIGHT STATEMENT (FOR US TYPE ONLY)
14.5 ISSUING LABELS WITH NET WEIGHT STATEMENT
(FOR US TYPE ONLY)
Menu: REG., M.DOWN, or REWRAP
Mode: FIX
Mode: FIX
When the initial settings #1-7 and #1-8 are set to 1, a Net Weight Statement is printed on the label.
A unit price and a tare registered in each PLU are printed as a price and a net weight.
A unit price and a tare registered in each PLU are printed as a price and a net weight.
Example) The preset Price is $2.10 and the preset Net Weight is 12 oz. The store knows that the actual
Net Weight of this commodity is 19 oz. and decides to sell it at $2.00.
Enter the PLU #.
8
1
6
2
1
9
3
0
0
PLU
PRT
*
FOR
PRT
*
The label is issued.
The label is issued. (Labels of identical
print data will automatically be issued
consecutively by peeling the label off the
backing paper.)
print data will automatically be issued
consecutively by peeling the label off the
backing paper.)
PLU
C
C
Press:
Enter the new price.
Press:
Enter the new weight.
(unit of weight: oz
displayed in the incremental
display method, i.e., the data
is shifted to the left as each
digit value is entered.)
(unit of weight: oz
displayed in the incremental
display method, i.e., the data
is shifted to the left as each
digit value is entered.)
Press:
Enter the quantity.
Press:
AUTO
MANUAL
Initial set #7-1: 1
Initial set #1-7: 0
Press, to return the PLU data to the
PLU file.
PLU file.
Press, to cancel label
issue temporarily.
issue temporarily.
Press, to cancel
label issue.
label issue.
Initial set #7-1: 0
Initial set #7-1: 1