Specific Conversion Procedures
How to Convert Gas Valve from Regulated to 
Unregulated
NOTE: Conversion from regulated to unregulated 
is only needed when regulated tumble dryers were 
ordered, but unregulated tumble dryers were 
needed.
Refer to Table 2.
1. Disconnect electrical power from tumble dryer. 
Close gas shut-off valve to tumble dryer. Refer to 
2. Follow instructions in Conversion Kit.
3. Change burner orifice size as required by the 
appropriate table according to How to Change 
Burner Orifice Size.
4. Commission tumble dryer for use.
How to Change Burner Orifice Size
1. Disconnect electrical power from tumble dryer. 
Close gas shut-off valve to tumble dryer. Refer to 
2. Remove gas valve:
Remove the burner orifice(s) from the spud 
holder. When converting from Natural Gas to 
L.P. Gas, the left-most burner and orifice (viewed 
from front) must be removed. In place of the 
removed orifice, a blank orifice (Part No. 
M400995) and a Burner Opening Cover (Part 
No. M413099) must be installed. 
3. Install the new, correct orifices. Refer to 
Figure 4. Torque each to 9-10 Nm.
4. Reinstall spud holder assembly to gas valve, 
making certain orifice(s) are in line with burner 
tube opening.
5. Commission tumble dryer for use.
NOTE: Blank burner orifices are available as 
Part No. M400995.