American Dryer Corp. WDA-385 用户手册

下载
页码 57
42
4. Check for voltage across TB#4 and TB#7.  If voltage
is evident, problem is defective burner hi-limit switch
P/N: 130401 or the sail switch* P/N: 122200, or the
harness connecting these two (2) devices to the
terminal (block #4 and #2).
5. Check for voltage across TB#3 and TB#7.  If voltage
is evident, problem is defective basket hi-limit switch
P/N: 130103 or the harness connecting this device
to the terminal block #3 and #4.
6. Check for voltage across the computer's 15-pin
connector, #4 (orange wire), and GND.  Spade
terminal on the computer.  If voltage is evident,
problem is the orange wire from the computer's 15-
pin connector, #4 to the terminal block #3.  There is
a bad connection on either end or faulty computer.
*  Make sure the sail switch damper is closing properly.
If so, check to see if it is making contact with the
switch.  If the sail switch damper is not closing
properly check for exhaust restriction, or exhaust
damper restriction and/or clogged lint screen.
NOTE: For models with a 3-phase motor, check rotation direction of impellor (fan) as noted on
label at rear of dryer.