Toshiba CS3950D 用户手册

下载
页码 23
 
 
 
   
D4133738B
 
(3)Restart / Reset 
Restart / reset available via ext. VD signal 
(Switching via rear panel DIP SW, Initial OFF) 
 
Notes : *  The  exposure-time  (shutter-speed)  is  determined  by  ext.   
VD interval. 
**  Enabled when rear-panel DIP SW OFF. 
***Provide Consecutive HD.
 
 
[Partial scan] 
(1)Operation mode 
 
 
 
 
 
 
 
 
 
 
Note:  Items  shown  as  [Option]  in  this  document  is  not  included  in  your  purchase  as 
standard components. Contact our dealer / distributor for details.
 
 
(2) Reset mode 
As shown in (1) above, non-reset and V-reset is available. 
([Option]: Doesn’t come as standard. Contact our dealer / distributor for details) 
 
(a) non-reset (Electronic shutter enabled) 
VD doesn’t get reset after video readout. The interval of VD signal is as follows. 
 
 
 
 
 
*Note: Under normal shutter mode, when non-reset is selected on partial scan, 
electronic shutter is valid. 
 
 
Please note that the exposure time is shortened than the setting value 
when the external VD is input at shorter than the above VD interval. 
 
(b) V-reset (Electronic shutter disabled) 
VD  does  get  reset  after  video  readout.  Under  internal  sync,  the  interval  of  VD  signal  is  as 
follows.
 
 
 
 
 
 
 
 
Note: Items shown as [Option] in this document is not included in your purchase as standard 
components. Contact our dealer / distributor for details. 
No
Scan mode
Sync
Reset
E-shutter Normal
E-shutter RTS
1
Non-reset Enabled [Option]
Enabled
2
V-reset
Disabled
3
Consecutive HD VD IN Non-reset Enabled [Option]
Enabled
4
Consecutive HD (VD) IN
V-reset
Disabled
5
Non-reset Enabled [Option]
Enabled
6
V-reset
Disabled
7
Consecutive HD VD IN Non-reset Enabled [Option]
Enabled
8
Consecutive HD (VD) IN
V-reset
Disabled
Internal
1/2 partial
1/4 partial
Internal
1/2 partial scan 1/4 partial scan
796H
796H
VIDEO OUT
Partial A
Partial B
Partial C
VD Interval
1/2 partial scan 1/4 partial scan
387H
193H
VIDEO OUT
Partial A
Partial B
Partial C
Partial E
Partial D
VD interval