Notes:
• Exterior overshield is connected to the shells of the connectors on both ends.
• Exterior overshield is connected to the shells of the connectors on both ends.
• 3M part 14X26-SZLB-XXX-0LC is a complete cable assembly, including connectors.
• Unused pairs should be terminated in 100 ohms at both ends of the cable.
2.3 Power Supply
The camera uses a single voltage input, normally set to 12 Volts @ 0.45 Amps typ.
Ripple and noise is required to be < 20 mV RMS.
Power is supplied through a Hirose connector.
When installing the mating connector, be sure to line up the slots. This action will
assure that you will not bend any of the pins.
Ripple and noise is required to be < 20 mV RMS.
Power is supplied through a Hirose connector.
When installing the mating connector, be sure to line up the slots. This action will
assure that you will not bend any of the pins.
Hirose HR25-7TR-6P Receptacle
Pin #
Description
1 +12V
2 +12V
3 NC
4 GND
5 GND
6 NC
Fairchild Imaging • CAM/CCD 2KCL.TDI & CAM/CCD-4KCL.TDI Line Scan Camera User’s Manual • Rev C• 15 of 30