Toshiba CTX28 用户手册

下载
页码 495
Strata CTX670 Installation
Install Reserve Power
4-30
Strata CTX I&M        06/04
Reserve Battery Cabinet Components/Cables
The part names and descriptions of the reserve battery cabinet components and cables are shown in 
Reserve Power for One or Two Cabinets (Wall Mount)
1. Connect the black jumper wire (supplied with the PBTC-3M cable) from the positive terminal 
of one 12VDC battery to the negative terminal of the second 12VDC battery (
2. Ensure that a serviceable 10-amp fuse is installed in the in-line fuse holder of the PBTC-3M 
cable.
3. Connect the PBTC-3M battery cable white lead to the open positive terminal of the 12VDC 
battery. Connect the black lead to the open negative terminal of the second 12VDC battery.
Important!
The cabinet(s) must be connected to the (live) AC power source, and the power 
supply On/Off switch set to On prior to the final step of connecting the reserve 
power batteries to the power supply via the BATT+/- receptacle. If the batteries are 
connected after AC power is lost, reserve power will not function.
4. Connect the PBTC-3M battery cable two-prong male plug to the Base Cabinet power supply 
BATT +/- receptacle.
5. Repeat Steps 3 and 4 to connect a PBTC-3M to the Expansion Cabinet.
6. To test reserve power operation, disconnect system AC power plugs with power supply On/Off 
switches in the On position. The system should continue to operate without interruption.
Note
If connecting four batteries, follow the wiring diagram in 
Table 4-5
Reserve Battery Cabinet Components/Cables 
Option
Description
PBTC-3M 
A three-meter battery cable used to connect reserve power batteries to the system power 
supply when the system has less than three cabinets. One reserve power cable is required 
for each cabinet in a one or two cabinet system (wall or floor mount). The cable connects the 
CTX670 cabinet power supply directly to the battery terminals (a BBDB is not required).
BBDB
CTX670 reserve power battery distribution box is required when connecting reserve power 
batteries to three or more cabinets (wall or floor mount). The box is field installed into one of 
the CTX670 cabinet side panels.
The BBDB provides seven BBTC2A-2.0M, battery distribution cables to connect reserve 
power from the BDDB box to each individual cabinet power supply.
One or two BBTC1A-2.0M must be ordered separately when using the BBDB battery 
distribution box.
BBTC1A-2.0M
A two-meter battery cable used to connect reserve power batteries to the BBDB battery 
distribution box. One reserve power cable is required in a three or four cabinet system and 
two cables are required for five or more cabinet systems (wall or floor mount). The cable 
connects CTX670 BBDB box directly to the battery terminals.