Toshiba CTX28 用户手册

下载
页码 495
Rack Mount Cabinets
Step 12: (Optional) Install Reserve Power
Strata CTX I&M    06/04
5-15
Ra
c
k
 M
o
u
n
Ca
b
ine
ts
Reserve Battery Cabinet Components/Cables
The part names and descriptions of the reserve battery cabinet components and cables are shown in 
Important!
Reserve batteries can be installed in various configurations depending on backup 
time (
) and the number of cabinets (
). Use the guide in 
 for installing batteries, as required.
WARNING!
Battery cables that exit the cabinet(s) are not UL listed because of 
possible incorrect installations. Have a licensed electrician install these 
cables.
Table 5-2
Reserve Battery Cabinet Components/Cables for Rack Mount Cabinets 
Option
Description
PBTC1A-3M 
A three-meter long battery cable is used to connect reserve power batteries to the system 
power supply when the system has less than three cabinets. One reserve power cable is 
required for each cabinet in a one or two cabinet system. The cable connects the Strata rack 
cabinet power supply directly to the battery terminals (a BBDB1A is not required).
BBDB1A
Strata CTX reserve power battery distribution box is required when connecting reserve 
power batteries to three or more cabinets. The box is field installed into one of the Strata CTX 
cabinet side panels.
The BBDB1A provides seven BBTC2A-2.0M, battery distribution cables to connect reserve 
power from the BDDB1A box to each individual cabinet power supply.
One or two BBTC1A-2.0M must be ordered separately when using the BBDB1A battery 
distribution box.
BBTC1A-2.0M
A two-meter battery cable used to connect reserve power batteries to the BBDB1A battery 
distribution box. One reserve power cable is required in a three or four cabinet system and 
two cables are required for five, six or seven cabinet systems. The cable connects Strata 
CTX BBDB1A box directly to the battery terminals.