Rack Mount Cabinets
Primary Power Cabinet Hardware
5-24
Strata CTX I&M    06/04
Primary Power Cabinet Hardware
The type of cabinet mounting can have an effect on the power requirements. Underwriters’ 
Laboratory (UL) and local electrical codes require certain standards for connecting commercial 
AC and reserve power to the Strata CTX system.
 describes which assemblies may be 
required to meet UL and local electrical code standards. 
Table 5-3
Power Cabinet Hardware for Rack Mount Cabinets 
Option
Description
BRPSB120A
Cabinet power strip for 120VAC primary power – provides three standard 120VAC/15A 
outlets (NEMA5-15R) and nine ft. AC power cord with standard 120VAC/15A plug (NEMA5-
15P). This unit is field installed outside the system cabinet on the back cover. The system 
can use 12 amps. (max.).
One BRPSB120A is required for two cabinet systems if the local electric code allows only 
one AC power cord to be connected to the system. 
Note
If the local electric code allows only one AC power cord to be connected to the 
system, 208VAC or 240VAC must be used as primary AC power for systems with four 
or more cabinets. 
One BRPSB120A is required for a three or four cabinet system if the local electric code 
allows two AC power cords connected to the system.
Two BRPSB120As are required for a five cabinet system if the local electric code allows two 
AC power cords connected to the system.
BRPSB240A
Cabinet power strip for 208VAC or 240VAC primary power - provides three 240VAC/20A 
outlets (NEMA 6-20R) and 9ft. AC power cord with a standard 240VAC/20A plug (NEMA 6-
20P). This unit is field installed outside the system cabinet on the back cover. The system 
can use 16 amps. (max.).
One BRPSB240A is required for two or three cabinet systems. 
Two BRPSB240As are required for four or five cabinet systems.
Three BRPSB240As are required for six or seven cabinet systems.
Note
Local electric codes allow only one AC power cord to be connected to the system when 
using 208VAC or 240VAC as the primary AC power. 
BRPSB240A conforms to the National Electric Code standards. If using 208VAC as 
primary power, the plug on the BRPSB240A AC power cord that exits the cabinet (NEMA 
6-20P) may have to be changed to a twist-lock type by a certified electrician to conform 
with local electric codes. 
BACL240A
AC208V or AC240VAC nine ft. power supply cord. The cord is rated at 10 amps. (max.) and 
must be used when the system is powered by 208VAC or 240VAC. One cord is required for 
each cabinet power supply and must be ordered separately only if using 208VAC or 240VAC 
as the system primary AC power.
Note
The cord is equipped with a 250VAC/20A plug (NEMA 6-20P) which is standard for 
240VAC. If using 208VAC as the system primary power this cord may have to be 
changed by a certified electrician for one or two cabinet installations. If using three or 
more cabinets, a BRPSB240A power strip is required and the power strip plug may 
have to be changed by a certified electrician depending on local electric codes.