PCB Installation
BWDKU1A – Digital Telephone Interface Unit
Strata CTX I&M        06/04
6-17
PC
B
 In
stal
latio
n
BWDKU1A – Digital Telephone Interface Unit
Circuits per PCB:
16 digital telephone circuits
Interfaces with:
all Toshiba digital telephones (corded and cordless, DDCB, DSS, ADM, BPCI)
CAUTION!
Existing SpectraLink interface units are not compatible with the 
BWDKU1A. A firmware update will be available from Spectralink in the 
near future.
When installing Add-on modules, be sure to check 
 
to verify maximum line lengths. BWDKU supports 1 pair wiring per 
Older Version(s):
none
The BWDKU1A is very similar to the BDKU + BDKS, but it supports 16 DKT circuits with a 
single PCB. It is also compatible with Strata DK but only supports eight circuits.
BWDKU1A Installation
1. See 
 and 
, then make any jumper adjustments needed for DKT or slot 
requirements. The BWDKU1A can be installed in any slot; however, if it is installed in 
expansion slots S_07~S_10, you must move the jumper plug to the “8 CCT” position. 
Important!
Do not detach the SWDR1A subassembly. The BWDKU1A will not work properly 
without it.
2. Insert the BWDKU1A (component side facing right) into the appropriate slot, and apply firm, 
even pressure to ensure proper mating of connectors.
Table 6-8
BWDKU1A Slot Placement
Slot Numbers
Available 
Circuits
BWDKU1A Jumper Settings
Base & Expansion 
S_0 ~S_06
16
The CTX identifies the BWDKU1A as a BDKU + BDKS. Leave jumper plug 
503 in the “BDKU” position and leave P504 in the “16 CCT” position.
Expansion 
S_07~S_10
8
Move jumper 504 to the “8 CCT” position when the BWDKU1A is placed in 
slots S_07~S_10. The BWDKU1A will work like a BDKU on a CTX system.
Note
If the BWDKU1A is installed on DK system, move jumper P503 to 
the “PDKU” position.