Toshiba CTX28 用户手册

下载
页码 495
T1
RDTU3A Call Data Information
8-10
Strata CTX I&M        06/04
RDTU3A Call Data Information
RDTU3A has an RS-232C port to trace data that the RDTU3A sends and receives from the CTX 
system processor. The T1 line alarm data can also be monitored with the RDTU3.
Commands
You can type the commands in the following table to check the status indicators also described in 
the table below.
Table 8-7
RDTU3 Status Commands
Command
Function
Format
Indication
U
When you power 
On or when you 
enter “U,” the unit 
name and software 
version appears.
u [RTN] 
RDTU3A © TOSHIBA 2002 VER.1A
UNIT MODE:FFMxx SCHxx TSxx RPDxxxx TPDxxxx 
ZCSxx
ERR:CRCyyy SLPyyy FSYyyyy BPVyyyyy
ALARM:YA on/off BA on/off FSL on/off
CRC = CRC Error in ESF mode
SLP = Slip error
FSY = Frame Sync error
BPV = Bipolar violation error
CH
Channel mode 
check command
C v [RTN] 
v = 0 to 23
Note: H = 1 
or 0
CH.vv : DTxx   DRyy DDTon/off
CH MODE: Ax
Explanation:
CH.vv:vv = channel numbers 0~23
DTxx:xx = DHin data code for RDTU3A to RCTU (see 
)
DTyy:yy = DHout datacode RCTU to RDTU3A (see 
)
DDTon/off: 
DDT1 = RDTU cannot receive requests from the central 
processor at this time (see following Notes).
DDT0 = RDTU is available to receive requests from the 
central processor
CH MODE:
A8 = CO loop, A0 = CP grpimd. AA = Tie immediate, AB = 
Tie Wink, AC = DID Immediate, AD = DID WInk
This information is the same as “2-2 Data-HWY code” and 
“2-5 Channel Trunk Type information.”
Loop back
Set RDTU3A into 
the Remote Loop 
Back mode
Useful for checking 
remote equipment.
When RDTU3A is in 
this mode, BSY 
LED will flush.
L [RTN]
 L
Quit Loop 
back
Quit Loop back 
mode
Q [RTN]
 Q