Toshiba CTX28 用户手册

下载
页码 495
Peripheral Installation
Power Failure Options
Strata CTX I&M        06/04
12-25
P
e
riphe
ra
l In
stal
latio
n
Power Failure Options
In the event of a power failure, Strata CTX uses these options:
Reserve Power
For information on the Reserve Power Option, see Chapter 1 – Installation.
Power Failure Transfer Unit
An optional Power Failure Transfer Unit (DPFT) can be installed that automatically connects up to 
eight selected CO lines directly to designated standard telephones in the event of a power failure. 
The DPFT enables normal operation of the selected CO lines and standard telephones when the 
system is in service. When power is restored, each telephone is independently reconnected to 
system standard telephone circuit ports after it is finished with its direct CO line call. The DPFT is 
normally installed on the MDF.
 provides a circuit diagram of the DPFT.
Figure 12-25 DPFT Circuit Diagram
J2-26
J2-1
J1-26
J1-1
Relay
J1-25
J1-50
J1-2
J1-27
J2-2
J2-27
Telephone Current
Detector
To TEL-T1
To TEL-R1
To CO-T1
To CO-R1
To RSTU/PSTU-T1
RDSU/RSTS
To RSTU/PSTU-R1
RDSU/RSTS
To RCOU/PCOU-T1
To RCOU/PCOU-R1
DG (Input)
-24V (Input)
RSTU or  PSTU
Control
1498
Notes
Representation of first of eight circuits.
Conditions shown with AC power (-24VDC) off.