Bosch THE DCN 用户手册

下载
页码 31
SC & SI Remote Interface Description 
en | 19 
 
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description 
5 System 
Installation 
Functions 
5.1 Introduction 
The system installation functions provide functionality to connect unit identification with the seat numbers 
used within the congress-hall. This process is also called seat-assignment. This chapter defines the set of 
remote functions needed for system installation. Each description is according to the definition given in 
section 3.1.1. 
5.2 SI_C_START_INSTALL 
Purpose 
Start the installation mode. The remote controller can choose among 2 modes of installation, which are: 
Mode 
Description 
SI_C_GLOBAL_INSTALL_MODE 
 
Global installation mode. When activating this mode, the CCU stops all 
applications running and only runs the installation application. When the 
function is successfully executed, the CCU has changed the system mode 
from congress to config. 
Entering the system mode config enables the update notification 
SI_C_REGISTER_UNIT which informs the remote controller about 
someone pressing a soft-key on a unit. The remote controller must use this 
notification message to link the unit with a seat. 
By pressing a soft-key on all units in order of the seat-numbers the remote 
controller can build a list of units with the seat-numbers as index. An 
example using this mode is presented in appendix Appendix C. 
SI_C_OPERATIONAL_INSTALL_MODE 
 
Operational installation mode. During this mode all applications keep on 
running. The CCU remains in the congress mode. 
No special update notification for registration will be enabled. The remote 
controller must select a proposed unit and the seat-number must be 
searched to link them together. 
To finish the installation the remote controller must execute the function SI_C_STOP_INSTALL. 
Availability 
This function is available in CCU system mode congress. 
Parameter structure for the function 
The function requires the following information as parameter: 
WORD 
 wInstallMode; 
where: 
wInstallMode 
The installation mode to be used. This parameter can have one 
of the following values: 
•  SI_C_GLOBAL_INSTALL_MODE 
•  SI_C_OPERATIONAL_INSTALL_MODE 
Response structure from the function 
The function has no response parameters. 
Error codes returned 
SI_E_NOERROR 
SI_E_FAILED   
 
(SI mode already in use) 
Update Notifications 
SC_C_CCU_MODE_CHANGE 
Related functions 
SI_C_STOP_INSTALL 
SI_C_SELECT_UNIT 
5.3 SI_C_STOP_INSTALL 
Purpose 
This function stops the installation started with the function SI_C_START_INSTALL. The CCU will return to 
normal congress mode if that is not the current system mode. The selected units will be deselected.