Bosch ICP-CC488 用户手册

下载
页码 118
ICP-CC488 | Installation Guide | 5.0  
System Functions 
EN | 22 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
To delete a remote radio User Code: 
1.  Enter the Master Code and press [1][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. 
2.  Enter the user number (9 to 16) you want to 
delete and press [AWAY].  
Two beeps sound and the corresponding zone 
indicators light. Refer to Table 18 on page 21. 
3.  Press [STAY] to delete the User Code. 
Two beeps sound and the STAY and AWAY 
indicators are extinguished. 
4.  Repeat Steps 1 to 3 to delete another remote 
radio User Code. 
 
This function is automatically terminated if 
you do not press a button within 60 sec 
or if you press [AWAY]. 
One long beep indicates that you 
selected an incorrect user number. 
5.0   System Functions 
This section explains more advanced features, such 
as Installer Code, Master Code, and hold-down 
functions that are required for testing and regular 
maintenance of the system.  
5.1 
Installer Code Functions 
Installer Code functions allow the installer to perform 
various system tests and tasks without knowing a 
Master Code. 
To access the required Installer Code function, enter 
the Installer Code and corresponding function digit, 
and press [AWAY]. The Installer Code functions are 
listed in Table 19 on page 22. 
You can access these functions only when the system 
is disarmed. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Table 19:  Installer Code Functions 
 
Function 
Description 
Add/delete RF wireless devices 
(Refer to Section 5.1.1
Set the number of days until the first Test 
Report 
(Section 5.1.2
Change domestic telephone numbers 
(Section 5.1.3
Change the Telco arm/disarm sequence 
(Section 5.1.4
Set STAY Mode 2 zones 
(Section 5.1.5
Satellite Siren (EDMSAT) Service Mode 
(Section 5.1.6
Turn Telephone Monitor Mode on and off 
(Section 5.1.7
Walk Test Mode 
(Section 5.1.8
Event Memory Recall Mode 
(Section 5.1.9
5.1.1 
Add or Delete RF Wireless Devices 
The control panel can accept up to 16 wireless 
devices on any or all of the eight zones used by the 
system. It is possible to connect wireless PIRs, reed 
switches, and smoke detectors directly to the control 
panel. You can allocate multiple wireless devices to 
each zone (for example, you can allocate up to 16 
wireless devices to Zone 1 and hard wire the 
remaining seven zones). Refer to Section 20.3 Default 
RF Device Mapping (Devices 1 to 8)
 and Section 20.4 
Default RF Device Mapping (Devices 9 to 16)
 for more 
information. 
To program an RF wireless device: 
1.  Enter the Installer Code and press [0][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. 
2.  Enter the RF device number (1 to 16) you want 
to change and press [AWAY].  
Two beeps sound and the corresponding 
codepad indicators light to show the RF device 
number you selected. 
3.  Enter the nine-digit RF ID number found on the 
back of the RF device and press [AWAY].   
Two beeps sound and the STAY and AWAY 
indicators are extinguished. 
4.  Repeat Steps 1 to 3 to add another device. 
 
This function is automatically terminated if 
you do not press a button within 60 sec 
or if you press [AWAY]. 
One long beep indicates that you 
selected an incorrect user number.