Bosch ICP-CC488 用户手册

下载
页码 118
ICP-CC488 | Installation Guide | 12.0  
Dialer Options 
EN | 52 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
Program the Ring Count to 14 to enable Answering 
Machine Bypass in the secondary mode. In this case, 
call the control panel and allow the phone to ring no 
more than twice and hang up. Wait a minimum of 8 
sec and call the control panel again. The control 
panel answers on the first ring. If you do not wait the 
8 sec, the control panel does not answer the call. To 
enable Answering Machine Bypass only when the 
system is armed, select Option 2 in Location 177 
(refer to Section 12.1 Dialer Options 1 on page 52). 
 
Set the Ring Count for the answering 
machine or facsimile machine to a value 
greater than two rings. Four to six rings is 
preferred. 
Program a 0 into this location to disable 
the control panel from answering an 
incoming call. 
 
11.11  Telephone Line Fault Options 
Location 
176 
Default 
Display FAULT indicator when telephone line fails 
Sound alarm when system is armed 
Sound alarm when system is disarmed 
8 Reserved 
This location has three options. You can select any 
combination of these options by programming a 
single value. Calculate this value by adding the 
option bit numbers together. Refer to Section 7.3 
Programming Option Bits
 on page 36 for more 
information. 
The control panel monitors the telephone line. If the 
telephone line is cut or disconnected for longer than 
40 sec, the control panel lights the FAULT indicator 
on the codepad. The FAULT indicator is 
extinguished after the telephone line is restored for 
longer than 40 sec. 
 
Options 2 and 4 do not operate unless 
you also enable Option 1. 
1 – Display FAULT indicator When the Telephone 
Line Fails 
When this options is selected, the FAULT indicator 
flashes and the codepad buzzer beeps once per min if 
the control panel detects that the telephone line is 
disconnected. Refer to Section 3.13 Fault Descriptions 
on page 18 for more information. 
2 – Sound Alarm When System Is Armed 
You must also select Option 1 to use this option. If 
the control panel detects that the telephone line is 
disconnected when the system is armed, the horn 
speaker, bell, and strobe outputs are activated. If only 
one audible alarm per arming cycle is required, select 
the Lockout Telephone Line Fail Alarm option (2) in 
Location 179 (refer to Section 12.3 Dialer Options 3 on 
page 53). 
4 – Sound Alarm when System Is Disarmed 
You must also select Option 1 to use this option. If 
the control panel detects that the telephone line is 
disconnected when the system is disarmed, the horn 
speaker, bell, and strobe outputs are activated. If only 
one audible alarm per arming cycle is required, select 
the Lockout Telephone Line Fail Alarm option (2) in 
Location 179 (refer to Section 12.3 Dialer Options 3 on 
page 53). 
 
If you program 7 in this location, the horn 
speaker, bell, strobe, and EDMSAT 
outputs are all activated when the system 
is armed or disarmed. 
12.0  Dialer Options 
Locations 177, 178, 179, and 180 have up to four 
options per location available for programming. You 
can select any combination of the options by 
programming a single value. Calculate this value by 
adding the option bit numbers together. Refer to 
Section 7.3 Programming Option Bits on page 36 for 
more information. 
12.1 Dialer 
Options 
Location
177 
Dialer reporting functions allowed 
Remote arming by telephone allowed 
Answering machine bypass only when armed 
Bell 103 used for FSK format  
(disabled = CCITT V21) 
1 – Dialer Reporting Functions Allowed 
If you select this option, the dialer operates for all 
functions. 
If you do not select this option, the communication 
dialer does not operate.  
Upload/Download using the CC816 Alarm Link 
Software and telephone remote arming remains 
operational regardless of this setting.