Bosch ICP-CC488 用户手册

下载
页码 118
ICP-CC488 | Installation Guide | 16.0  
Programmable Outputs 
EN | 71 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
16.1  Redirecting Outputs to the 
Codepad Buzzer 
Multiple output event types can be directed to the 
codepad buzzer so that the buzzer can indicate a 
number of events. 
To redirect an output to the codepad buzzer, select 
an output and program it for the desired Output 
Event Type. If the output is functioning correctly, 
add 8 to the first (tens) digit of the Output Event 
Type. 
Example 
3,0 Communications Failure 
This event operates after the dialer makes all possible 
attempts to reach the base station receiver. It is reset 
when the panel receives the first Kiss-off. This 
Output Event Type is not applicable to domestic 
reporting. 
To redirect this Output Event Type to operate a 
codepad buzzer, program the Output Event Type as: 
11,0 Communications Failure  
The codepad buzzer operates instead of the output 
that was programmed. Output 3 is no longer 
functional and cannot be used for any other Output 
Event Type.  
16.2 Output 
Event 
Types 
There are approximately 75 Output Event Types. 
Two numbers designate each Output Event Type. 
Program these numbers into the appropriate 
locations for the output. 
 
All reset times reference Polarity 1 and 8. 
Reset times vary depending on the 
selected polarity. 
0,0 
EDMSAT - Satellite Siren (Output 1 Only) 
This output controls all functions of the SS914 
Satellite Siren (EDMSAT). The Speaker Indication 
Beeps option does not function through the satellite 
siren for remote operations. No polarity is required 
for this Output Event Type. 
0,1 System 
Armed 
This output operates when the system is armed. The 
output is reset when the system is disarmed. If the 
system is partitioned, this output operates when both 
areas are armed in AWAY Mode or STAY Mode 1. 
0,2 System 
Disarmed 
This output operates when the system is disarmed. 
The output is reset when the system is armed. If the 
system is partitioned, this output operates when both 
areas are disarmed. 
0,3 
Armed in STAY Mode 
This output operates when the system is armed in 
STAY Mode 1 or STAY Mode 2. The output is reset 
when the system is disarmed. If the system is 
partitioned, this output operates when either area is 
armed in STAY Mode 1. 
0,4 
Armed in AWAY Mode 
This output operates when the system is armed in 
AWAY Mode. The output is reset when the system is 
disarmed. If the system is partitioned, this output 
operates when either area is armed in AWAY Mode. 
0,5 
Auto Arm Pre-Arming Alert Time 
This output operates during the time period before 
the control panel is automatically armed in AWAY 
Mode or STAY Mode 1. The output is reset when 
the control panel is automatically armed in AWAY 
Mode or STAY Mode 1. The Auto Arming Pre-Alert 
Time is programmed in Location 481 (refer to Section 
17.11
 for more information). 
0,6 
Exit Warning with All Zones Sealed or 
Entry Warning 
This output operates during Exit Time when the 
control panel is armed and all zones are sealed. The 
output is reset when Exit Time expires.  
This output operates again during Entry Time and is 
reset when Entry Time expires or the system is 
disarmed.  
This output also operates if a zone is activated when 
the system is armed in STAY Mode 1 or STAY 
Mode 2 and the Entry Guard Timer for STAY Mode 
is programmed in Locations 472 and 473 (refer to 
Section 17.5 on page 78). 
0,7 Exit 
Warning 
This output operates during Exit Time when the 
system is armed. The output is reset when Exit Time 
expires. 
0,8 Exit 
Warning 
Finished 
This output operates after Exit Time expires when 
the system is armed. The output is reset when the 
system is disarmed.  
0,9 
Kiss-Off after Exit Time 
This output operates after the first successful 
transmission to the base station receiver when Exit 
Time expires. The output is reset when the system is 
disarmed. 
0,11 Entry 
Warning 
This output operates when during Entry Timer 1, 
Entry Timer 2, or Entry Guard Timer for STAY 
Mode. The output is reset when the Entry Time 
expires.