Bosch DX4010I 用户手册

下载
页码 12
DX4010i | Installation Instructions | 1.0 
General Information 
 
 
Bosch Security Systems, Inc. | 1/05 | 4998141106C 
 
 
1.0 General 
Information 
The DX4010i is a data terminal equipment (DTE) 
configured RS-232 serial device interface (SDI) module 
designed to operate with compatible control panels. It 
connects to the control panel through the option or 
SDI data bus. 
The DX4010i is used to connect a PC with RPS, BIS, 
PC 9000, CMS 7000, or other third party software that 
uses a serial conncetion to the supported control 
panels. The module also supports a serial printer (or 
parallel printer with a convertor box) for control panels 
that support a serial printer. The compatibility lists in 
Table 1 show support information. 
2.0 Specifications 
Table 1:  DX4010i Specifications 
 
 
 
 
Operating 
Voltage 
12 VDC 
Current Draw 
50 mA nominal, 55 mA with diagnostic 
LEDs enabled 
Communication 
Configuration 
Programmable through the control 
panel. Refer to the appropriate control 
panel programming instructions. 
 
 
The baud rate for the printer output on a 
DS7400Xi must be greater than 300 baud. 
Operating 
Temperature 
0°C to +50°C (+32°F to +122°F) 
Relative 
Humidity 
5 to 85% @ +30°C (+86°F) 
non-condensing 
Control Panel 
Compatibility 
Option bus control panels: D6412, 
D4412, DS7240, DS7220, DS7400Xi 
(v2.02 or higher) 
SDI bus control panels (v6.0 or higher): 
D9412G, D7412G, D7212G, D9124, 
D9112, D7412, and D7212 
Application 
Compatibility 
RPS: supported on all compatible 
control panels 
PC 9000: supported on SDI Bus 
control panels (D9412G, D7412G, 
D7212G, D9112, D7412, and D7212) 
BIS: supported on SDI Bus control 
panels, v6.3 and higher (D9412G, 
D7412G, and D7212G) 
CMS 7000: supported on DS7400Xi 
Control Panels set at Mode 18 (v3.09 
or higher) 
Printers: supported on compatible 
Option Bus control panel 
 
 
Figure 1:  DX4010i Component Layout 
SER
R x
T x
BUS
Rx Tx
LED
 E NABL E
DB9  GND
ENA BLE
P1
P6
P2
P3
1
2
3
4
5
6
7
 
1-
 
DB9 GND enable pins (P1) 
2-
 
RJ-16 data bus connector (P3) 
3-
 
Data bus (TS1) 
4-
 
Address DIP switches (S1) 
5-
 
Diagnostic LEDs 
6-
 
Diagnostic LED enable pins (P2) 
7-
 
DB9 DTE RS-232 connector (P6) 
3.0 Installation 
Standards 
 
Failure to follow the instructions in this 
manual can result in personal injury or 
damage to the equipment. 
 
 
 
The DX4010i contains static-sensitive 
components and must be handled with 
care. Follow anti-static procedures when 
handling the modules. 
 
 
 
Test according to NFPA 72 if used in fire 
applications. 
 
1.
 
Disconnect power to the control panel by 
unplugging the transformer and removing the red 
battery lead. 
2.
 
Remove screws from enclosure cover to access the 
DX4010i board. 
3.
 
Connect circuit wiring and install jumper pins. 
Refer to Section 4.0 Wiring on page 5. 
4.
 
Replace enclosure cover. 
5.
 
Connect a serial cable to the serial device. Refer to 
Section 7.0 DB9 DTE RS-232 Connector (P6) on 
page 10. 
6.
 
Reapply power to the control panel.