Installation continued-   
 
Minimum Clearances 
 
      
WARNING
 
Failure to adhere to these installation and operating instructions may 
create a hazard to life and property and will nullify the warranty.
 
 
This installation shall allow access to the front of the water heater and 
adequate clearance shall be provided for servicing and operating this water 
heater. The water heater may be installed on either a combustible or non-
combustible floor.  If the water heater is to be installed directly on  carpeting, it 
shall be installed on top of a metal or wood panel (or equivalent) extending 
beyond the full width and depth of the appliance by at least three (3) inches  
(7.6 cm) in any direction or, if the appliance is to be installed in an alcove or 
closet, the entire floor shall be covered by the panel.  The minimum 
clearances to combustibles for this water heater are given in the tables on 
pages 10 through 13.  A minimum of 24 inches front clearance shall be 
provided for inspection and servicing. 
 
If it is necessary to install this water heater in an alcove on combustible 
flooring with clearances from combustible materials as shown in the tables on 
pages 10 through 13. 
 
 
 
 
 
 
 
 
 
 
Installation (Minimum Clearances) continued- 
CAUTION 
The National Fuel Gas Code (ANSI Z233.1-or latest edition) and  
CAN/CGA (B149.1-or latest edition), expressly prohibits the following: 
 
 
 
a) Installation of a water heater in a bathroom, bedroom, or any 
occupied room normally kept closed. 
 
b) Installation of a water heater in a garage, unless the unit is 
installed so that the burner and ignition devices are at least 
eighteen (18) inches (45.8 cm) above floor level and protected 
to avoid damage by a moving vehicle.
 