Large Dehumidifying Dryers 
Controls 
28 
Identifying Process Air Temperature Controller LED Indicators 
Indicator 
Name 
Description 
PV 
  8.8.8.8    
Process Value 
Numeric LED 
During normal operation, the process value (PV
numeric LED indicator displays the process 
temperature at the To Process thermocouple. It 
also lists parameters during setup and error 
messages if any errors occur. 
SV 
8.8.8.8
 
Set Value  
Numeric LED 
During normal operation, the set value (SV
numeric LED indicator displays the process set 
point temperature selected for the dryer. The dryer 
then maintains this set point temperature.  This 
LED indicator also displays parameter and pre-set 
function values during configuration setup. 
OUT1 
Out 1 LED 
Lit when Control Output 1 is on.   The Out1 
indicator lights when the controller signals the 
process heaters to be energized. 
OUT2 
Out 2 LED 
Lit when Control Output 2 is on.  Not used in 
this application. 
 AT 
AT LED 
Flashes during auto-tuning in process value (PV) 
screen.  
 
Indicator 
Name 
Description 
ALARM1 
ALARM 1 LED 
Lights in the Operation Indicator Section when 
the output function assigned to auxiliary output 
1 turns on.  
The ALARM1 indicator lights when 
the process temperature falls below the set point 
temperature by more than the alarm deviation 
value. Advisory alarm does not interrupt operation 
of the dryer. 
 
 
 
Indicator 
Name 
Description 
ALARM2 
ALARM 2 LED 
Lights in the Operation Indicator Section when 
the output function assigned to auxiliary output 
1 turns on.  
The ALARM2 indicator lights when 
the process temperature exceeds the set point 
temperature by more than the alarm deviation 
value. Alarm output de-energizes the heaters. 
Heaters re-energize when the temperature falls 
within the acceptable range.